28
MZ-G750/R700
60. Press the Xkey.
(0D65 is blinking)
61. Press the [VOL+] key once to change the blinking portion to
0D75.
62. Press the xkey.
(00 is blinking)
63. Adjust with the [VOL+] key (adjusted value up) or [VOL--]
key (adjusted value down) so that the adjusted value becomes
1C.
64. Press the Xkey.
(0D75 is blinking)
65. Press the [VOL+] key once to change the blinking portion to
0D76.
66. Press the xkey.
(00 is blinking)
67. Adjust with the [VOL+] key (adjusted value up) or [VOL--]
key (adjusted value down) so that the adjusted value becomes
03.
68. Press the Xkey.
(0D76 is blinking)
69. Press the [VOL+] key to change the blinking portion to 0D78.
70. Press the xkey.
(00 is blinking)
71. Adjust with the [VOL+] key (adjusted value up) or [VOL--]
key (adjusted value down) so that the adjusted value becomes
01.
72. Press the Xkey.
(0D78 is blinking)
73. Press the [VOL+] key once to change the blinking portion to
0D79.
74. Press the xkey.
(00 is blinking)
75. Adjust with the [VOL+] key (adjusted value up) or [VOL--]
key (adjusted value down) so that the adjusted value becomes
E0.
76. Press the Xkey.
(0D79 is blinking)
77. Press the [T MARK] key for several seconds (about 3 seconds)
to exit the patch data write mode (to return to the manual mode
display in the test mode).
78. Press the Xkey to write the modified data. (The adjusted value
changes to CC)
79. The modified data writing is over, if the adjusted value changes
to DD.
80. Turn the power off.
This set LCD display
0 230D7500
00: Adjusted value
This set LCD display
0 230D751C
1C: Adjusted value
This set LCD display
0 230D7600
00: Adjusted value
This set LCD display
0 230D7603
03: Adjusted value
This set LCD display
0 230D7800
00: Adjusted value
This set LCD display
0 230D7801
01: Adjusted value
This set LCD display
0 230D7900
00: Adjusted value
This set LCD display
0 230D79E0
E0: Adjusted value
This set LCD display
0 23Patch 01
01: Adjusted value
This set LCD display
0 23 SDD
DD: Adjusted value