25
MZ-G750/R700
25. Press the Xkey.
(0D61 is blinking)
26. Press the [VOL+] key once to change the blinking portion to
0D62.
27. Press the xkey.
(00 is blinking)
28. Adjust with the [VOL+] key (adjusted value up) or [VOL--]
key (adjusted value down) so that the adjusted value becomes
04.
29. Press the Xkey.
(0D62 is blinking)
30. Press the [VOL+] key once to change the blinking portion to
0D65.
31. Press the xkey.
(00 is blinking)
32. Adjust with the [VOL+] key (adjusted value up) or [VOL--]
key (adjusted value down) so that the adjusted value becomes
20.
33. Press the Xkey.
(0D65 is blinking)
34. Press the [T MARK] key for several seconds (about 3 seconds)
to exit the patch data write mode (to return to the manual mode
display in the test mode).
35. Press the Xkey to write the modified data. (The adjusted value
changes to CC)
36. The modified data writing is over, if the adjusted value changes
to DD.
37. Turn the power off.
Modified Data Writing Method (version 1.100)
1. Select the manual mode of the test mode, and set item number
023 (see page 13).
2. Press the [VOL+] key once to change the adjusted value to 01.
3. Press the [T MARK] key for several seconds (about 3 seconds)
to activate the patch data write mode.
(The following display will appear where 00 is blinking)
4. Press the Xkey.
(0D5C is blinking)
5. Press the [VOL+] key once to change the blinking portion to
0D5D.
6. Press the xkey.
(00 is blinking)
7. Adjust with the [VOL+] key (adjusted value up) or [VOL--]
key (adjusted value down) so that the adjusted value becomes
AA.
8. Press the Xkey.
(0D5D is blinking)
9. Press the [VOL+] key once to change the blinking portion to
0D5E.
10. Press the xkey.
(00 is blinking)
11. Adjust with the [VOL+] key (adjusted value up) or [VOL--]
key (adjusted value down) so that the adjusted value becomes
04.
This set LCD display
0 230D6204
04: Adjusted value
This set LCD display
0 230D6500
00: Adjusted value
This set LCD display
0 230D6520
20: Adjusted value
This set LCD display
0 23Patch 01
01: Adjusted value
This set LCD display
0 230D61A1
A1: Adjusted value
This set LCD display
0 230D6200
00: Adjusted value
This set LCD display
0 23 SDD
DD: Adjusted value
This set LCD display
0 23Patch 00
00: Adjusted value
This set LCD display
0 230D5C00
00: Adjusted value
This set LCD display
0 230D5D00
00: Adjusted value
This set LCD display
0 230D5DAA
AA: Adjusted value
This set LCD display
0 230D5E00
00: Adjusted value