Setting the Time Data
64
Chapter 3 Adjustments and Settings
Example 2: Interconnecting a number of
camcorders (including one reference
camcorder)

To lock the timecode to an external

source

1Turn on the POWER switch.
2Set the PRESET/REGEN/CLOCK

switch to PRESET.

3Set the F-RUN/SET/R-RUN switch to

F-RUN.

4Set the DISPLAY switch to TC.
5Supply a timecode signal and a

reference video signal complying with

the SMPTE standard and in proper

phase relationship, to the TC IN

connector and to the GENLOCK IN

connector, respectively.

This operation synchronizes the internal
timecode generator with the external
timecode. After about 10 seconds, you can
disconnect the external timecode without
losing the synchronization.
Notes
• When you finish the above procedure, the internal
timecode is immediately synchronized with the
external timecode and the counter display will show
the value of the external timecode. However, wait for
a few seconds until the sync generator stabilizes before
recording.
• If the frequency of the reference video signal is not the
same as the system frequency of the camcorder, the
camcorder cannot be correctly genlocked. In such a
case, the internal timecode is not correctly
synchronized with the external timecode.
User bit settings during timecode
synchronization
When the timecode is synchronized, only the ti me
data is synchronized with the external timecode
value.
To release the timecode synchronization
First disconnect the external timecode, then set
the F-RUN/SET/R-RUN switch to R-RUN.
To change the power supply from the battery
pack to an external power supply during
timecode synchronization
To maintain a continuous power supply, connect
the external power supply to the DC IN connector
before removing the battery pack. You may lose
timecode synchronization if you remove the
battery pack first.
Camcorder synchronization during timecode
synchronization
During timecode synchronization, the camcorder
is genlocked to the reference video signal input
from the GENLOCK IN connector.
1VIDEO OUT connector
2TC OUT connector
3TC IN connector
4GENLOCK IN connector
To another camcorder to be synchronized