TC-FX45
SECTION 3
ADJUSTMENTS
3 - 1 . M E C H A N I C A L A D J U S T M E N T S
PRECAUTION
1.Clean the following parts with a denatured-
record/playback head | pinch | roller |
erase head | rubber | belts |
capstan | idlers |
|
2.Demagnetize the record/playback head with a head demagnetizer.
3.Do not use a magnetized screwdriver for the adjustments.
4.After the adjustments, apply suitable locking compound to the parts adjusted.
5.The adjustments should be performed with the rated power supply voltage unless otherwise noted.
lead Height Adjustment
1.Prepare an adjustment cassette as shown below.
C- 1 | Cur out hatched |
tape cassette | portions. |
2.In playback mode and viewing from the front, adjust the head heights to eliminate tape curl and tape twist at portions of the arrow.
erase head record/playback
>;
Torque Measurement
|
|
|
|
| 1 | ||
Torque | Torque meter |
|
|
| Meter reading | ||
|
|
|
|
|
|
|
|
Forward | CQlO2C | ’ |
|
| 28- | ||
| (0.38 - 0.83 | ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 2.5 - |
Back Tension |
|
|
|
| |||
|
|
| (0.03 - 0.07 | ||||
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
Fast Forward |
|
|
|
| 80 - 165 | ||
and Rewind |
|
|
| (1.1 - 2.2 | |||
|
|
|
|
|
|
|
|
Pinch Roller Pressure Measurement
- Playback Mode -
@ Slowly return he pinch roller and read the spring scale just when the pinch roller starts rotating. (The capstan should
pinch roller
\
0 tension gauge
Soft Eject Adjustment
Specification
Set the tape
fast
slow
@