Control
Feature Controls
This camera supports the following features.
Shutter | Controls the exposure time. Can be controlled by both relative control values from 1/100000 of a second to 1/15s, allocated |
| from 1 to 3196. |
|
|
Gain | Can be changed to 0 to 18 dB, subdivided in 512 steps. |
|
|
Trigger | Sets external trigger mode. Trigger Mode 0 and 1 are available. Software Trigger Mode in which triggers can be output by |
| software. |
|
|
The
White Balance | Adjusts the White Balance by adjusting the R and B gain with respect to G. |
|
|
Hue | Adjusts G gain. Use this feature when you cannot obtain the correct White Balance using the R and B gain. |
|
|
Before sending a command, check the predetermined variable range and check whether the feature supports AUTO mode.
Address | Data | Bit* |
|
|
|
|
|
F0F0050Ch | 8900003Fh | 0 | This feature exists. |
(White Balance) |
| 4 | The value can be read out. |
|
|
|
|
| 7 | Manual setting can be selected. | |
|
|
|
|
|
| Min. 0 | |
|
| Max. 63 | |
|
|
|
|
F0F00510h | 8900003Fh | 0 | This feature exists. |
(Hue) |
| 4 | The value can be read out. |
|
|
|
|
| 7 | Manual setting can be selected. | |
|
|
|
|
|
| Min. 0 | |
|
| Max. 63 | |
|
|
|
|
F0F0051Ch | 89001C7Ch | 0 | This feature exists. |
(Shutter) |
| 4 | The value can be read out. |
|
|
|
|
|
| 7 | Manual setting can be selected. |
|
|
|
|
|
| Min. 1 | |
|
| Max. 3196 | |
|
|
|
|
F0F00520h | 89000200h | 0 | This feature exists. |
(Gain) |
| 4 | The value can be read out. |
|
|
|
|
|
| 7 | Manual setting can be selected. |
|
|
|
|
|
| Min. 0 | |
|
| Max. 256 | |
|
|
|
|
F0F00530h | 8C81C000h | 0 | This feature exists. |
(Trigger) |
| 4 | The value can be read out. |
|
|
|
|
|
| 5 | Feature can be switched between ON and OFF. |
|
|
|
|
|
| 8 | Trigger Source0 exists. |
|
| 15 | Software Trigger Mode exists. |
|
|
|
|
|
| 16 | Trigger Mode0 exists. |
|
| 17 | Trigger Mode1 exists. |
|
|
|
|
* According to the IEEE1394 specifications, the most significant bit is shown as 0.
Actual control can be carried out by setting registers from F0F00800 onward.
dddindicates the control value expressed as a 12 bit hexadecimal number. xxx indicates that any setting made will be ignored.
14 | |