Control

Feature Controls

This camera supports the following features.

Shutter

Controls the exposure time. Can be controlled by both relative control values from 1/100000 of a second to 1/15s, allocated

 

from 1 to 3196.

 

 

Gain

Can be changed to 0 to 18 dB, subdivided in 512 steps.

 

 

Trigger

Sets external trigger mode. Trigger Mode 0 and 1 are available. Software Trigger Mode in which triggers can be output by

 

software.

 

 

The XCD-V50CR supports the following additional features.

White Balance

Adjusts the White Balance by adjusting the R and B gain with respect to G.

 

 

Hue

Adjusts G gain. Use this feature when you cannot obtain the correct White Balance using the R and B gain.

 

 

Before sending a command, check the predetermined variable range and check whether the feature supports AUTO mode.

Address

Data

Bit*

 

 

 

 

 

F0F0050Ch

8900003Fh

0

This feature exists.

(White Balance)

 

4

The value can be read out.

 

 

 

 

(XCD-V50CR only)

 

7

Manual setting can be selected.

 

 

 

 

 

 

8-19

Min. 0

 

 

20-31

Max. 63

 

 

 

 

F0F00510h

8900003Fh

0

This feature exists.

(Hue)

 

4

The value can be read out.

 

 

 

 

(XCD-V50CR only)

 

7

Manual setting can be selected.

 

 

 

 

 

 

8-19

Min. 0

 

 

20-31

Max. 63

 

 

 

 

F0F0051Ch

89001C7Ch

0

This feature exists.

(Shutter)

 

4

The value can be read out.

 

 

 

 

 

 

7

Manual setting can be selected.

 

 

 

 

 

 

8-19

Min. 1

 

 

20-31

Max. 3196

 

 

 

 

F0F00520h

89000200h

0

This feature exists.

(Gain)

 

4

The value can be read out.

 

 

 

 

 

 

7

Manual setting can be selected.

 

 

 

 

 

 

8-19

Min. 0 (XCD-V50) or 256 (XCD-V50CR)

 

 

20-31

Max. 256 (XCD-V50) or 768 (XCD-V50CR)

 

 

 

 

F0F00530h

8C81C000h

0

This feature exists.

(Trigger)

 

4

The value can be read out.

 

 

 

 

 

 

5

Feature can be switched between ON and OFF.

 

 

 

 

 

 

8

Trigger Source0 exists.

 

 

15

Software Trigger Mode exists.

 

 

 

 

 

 

16

Trigger Mode0 exists.

 

 

17

Trigger Mode1 exists.

 

 

 

 

* According to the IEEE1394 specifications, the most significant bit is shown as 0.

Actual control can be carried out by setting registers from F0F00800 onward.