Operation

AD MODE Switch

The AD MODE switch is used to set the desired bit mode and sample rate.The follo- wing list explains the respective switch positions:

16 Bit Mode

E = AES

Ext. Synchronization to AES clock

D = DA

Synchronization zum D/A converter

C = WC

Ext. Synchronization to word clock

B = 48

Int. Synchronization to 48 kHz

A = 44,1

Int. Synchronization to 44,1 kHz

9

= 96

Int. Synchronization to 96 kHz

8

= 88,2

Int. Synchronization to 88,2 kHz

24 Bit Mode

0

= 88,2

Int. Synchronization to 88,2 kHz

1

= 96

Int. Synchronization to 96 kHz

2

= 44,1

Int. Synchronization to 44,1 kHz

3

= 48

Int. Synchronization to 48 kHz

4

= WC

Ext. Synchronization to word clock

5

= DA

Synchronization to D/A converter

6

= AES

Ext. Synchronization to AES clock

Error LEDs

The Error-LEDs indicate faulty audio signals at the S/P- DIF input or faulty sync signals at the WC/AES SYNC INPUT (=S/P-DIF output). In this case the respective signal is muted.