Safety Information

Product Overview

Installation

Diagnostics

Options and Accessories

Specification

Display

Fault

Action to Reset

Bridge Disabled

 

Motor Overtemp

Allow Motor to cool down,

Yes

 

Reset Button or Input Line

 

 

 

RMS Shunt Power

Reset Button or Input Line

Yes

Overspeed

Reset Button or Input Line

Yes

Following Error

(Pulse mode only)

Reset Button or Input Line

Yes

Travel Limit +/-

Auto

No

Sync Fault

Cycle Logic Power

Yes

Run Time

(EP-P Only)

Reset Button or Input Line

Yes

All "On"

Normally "On" for one second during power-

up

Yes

Fault Descriptions

Flash Invalid

This fault indicates that the firmware checksum has failed. From the Tools>Program Flash menu in PowerTools Pro the firmware stored in flash memory can be reprogram or upgrade. If this problem persists, call Control Techniques. A common cause would be an interrupted F/W Flash upgrade (cable disconnected during an upgrade process).

Power Up Test

This fault indicates that the power-up self-test has failed. This fault cannot be reset with the reset command or reset button.

44

Page 56
Image 56
Emerson 400518-01 installation manual Fault Descriptions, Flash Invalid