Safety Information

Product Overview

 

 

Installation

Diagnostics

Options and Accessories

Specification

Drive (J5)

A 1

A/ 9

B 2

B/ 10

Z 3

Z/ 11 Connector Shell

Internal

10 Ohm

PE

Note: If the external controller does not have an internal terminating resistor

R1, R2 and R3 must be mounted within 3 ft [1 m] of the external controller. A 120 ohm resistor is recommended for high frequency encoders (over 250 kHz) or cables longer than 25 feet. If encoder signals are multi-dropped, termination resistors are required only at the last drop point. Do not terminate at more than one point.

A

R1

A/

B

External

R2Controller

B/ Encoder

Input

Z

R3

Z/

Single Point

PE Ground

= Twisted Pair

Figure 35: Analog/Sync Output Connector (J5) Encoder Output Wiring

Figure 36: Direction Convention Diagram

Installation

33

Page 45
Image 45
Emerson 400518-01 installation manual Drive J5, Connector Shell