Front View

L1

L2

PE

Wire crimp ferrules are recommanded: For ground lead use -

Pheonix Contact p/n AI-TWIN 2X1, 5-8Bk/32 00 82 3 American Electrical/DigiKey 1381015/288-1130-ND

For motor leads use -

Pheonix Contact p/n AI 1,5-8 RD/32 01 13 6 or ALTEC p/n H1.5/14 2204.0 Pk/100

NT or MG Motor

Power Connection

MOTOR

R

S

T

24 Vdc

 

EP204-I00-0000 9606XX-XX A1 SN 0610E014

Brown

Black

Blue

Green/Yellow

Shield

Important: PE ground should connect to drive and motor only. Nothing should be connected between these devices.

Tighten screws to 5 in-lb.

R

S

T

Ground

Connector Shell

2" and 3" motor cable connector (CMDS-xxx cable)

Figure 16: Epsilon EP - NT/MG Motor Power Wiring Diagram