Emerson 400518-01 installation manual Specification

Models: 400518-01

1 88
Download 88 pages 22.24 Kb
Page 68
Image 68
Manual background

Safety Information

Product Overview

 

 

Installation

Diagnostics

Options and Accessories

Specification

Epsilon EP Series

 

Analog command: ±10 Vdc 14 bit, 100 kOhm impedance, differential

 

Absolute Maximum Input Voltage Input: +/- 14 Vdc to ground or differential, including

 

drive enable

Control Inputs

Digital Inputs: 5 on the EP-B and 16 on the EP-I and EP-P including the drive enable

 

 

input, 10 Vdc - 30 Vdc, 4.8 kohm impedance; current sourcing signal compatible (active

 

high); max input response time is 500 µs; optically isolated.

 

Input debounce: 0-2000 ms configured in PowerTools Pro

 

 

 

Diagnostic Analog Outputs: (2) ±10 Vdc into 10 Kohm (single ended), short circuit proof

 

to ground, short circuit proof to ground, 10 bit, software selectable output signals

 

Digital Outputs: 3 on EP-B, 8 on the EP-I and EP-P, 150 mA max each, short circuit

Control Outputs

proof, current source from 10 Vdc - 30 Vdc I/O power supply, 3.5 Vdc max supply to

 

output voltage drop @ 150 mA, opto-isolated

 

Motor temp sensor: Contact: 5 Vdc O.C. (tripped), 0.5 mA S.C. (normal)

 

Compatible with PTC thermistor with 1 kOhm resistance at trip point

 

 

 

Interface: Software selectable differential (RS422) or single ended (TTL Schmitt Trigger)

 

Maximum input frequency:

 

Differential - 1 MHz per channel; (4 million counts/second in quadrature),

 

0.5 µs minimum pulse width

Pulse Mode

Single ended - 500 kHz per channel; (2 million counts/second in quadrature),

 

1 µs minimum pulse width

 

Ratio Capabilities: 20 to 163,840,000 PPR

 

Single ended inputs have 1 kohm pull-up to 5 V

 

 

Encoder Output Signal

Differential line driver, RS-422 and TTL compatible

Scalable in one line increment resolution up to 2048 lines/rev of the motor (NT)

 

 

 

 

Energy storage available in bus caps:

 

EP202: 15 J @ 240 Vac, 30 J @ 120 Vac

Shunt Resistor Capacity/

EP204: 24 J @ 240 Vac, 63 J @ 120 Vac

EP206: 40 J @ 240 Vac, 104 J @ 120 Vac

Regeneration Capacity

 

 

EP204/EP206 External Shunt Control:

 

12 A peak, 2 kW max average power, 33 ohm minimum external resistor

 

 

 

25 mA AC and < 0.1 mA DC with 15 ft (4.6 m) CMDS motor power cable and NT-330

Earth Leakage Current and RCD

motor at 240 Vac. Leakage is higher with longer cables.

Compatibility

The EP drive is compatible with a Type A Residual current Detector (RCD) that allows

 

expected leakage currents.

 

 

56

Page 68
Image 68