Emerson 400518-01 installation manual Installation, Drive/Motor Combination, Suggested KVA Rating

Models: 400518-01

1 88
Download 88 pages 22.24 Kb
Page 27
Image 27
Drive/Motor Combination

Safety Information

Product Overview

 

 

Installation

Diagnostics

Options and Accessories

Specification

When multiple drives are connected to a single isolation transformer, add the suggested KVA ratings of the drives that would be operating simultaneously together for transformer sizing.

Drive/Motor Combination

Suggested KVA Rating

EP202/NT-207

1.2

 

 

EP202/NT-212

1.2

 

 

EP204/NT-207

1.2

 

 

EP204/NT-212

1.7

 

 

EP206/NT-212

1.7

 

 

EP206/NT-320

3.0

 

 

EP206/NT-330

3.0

 

 

EP206/NT-345

3.0

 

 

EP202/XV-402

0.2

 

 

EP202/XV-403

0.3

 

 

EP202/XV-604

0.8

 

 

EP202/XV-606

0.8

 

 

EP204/XV-6011

1.3

 

 

EP204/XV-8017

2.0

 

 

EP204/XV-8022

2.2

 

 

EP204/XV-8023

2.1

 

 

EP206/XV-8014

2.0

 

 

EP206/XV-8022

2.2

 

 

EP206/XV-8023

2.1

 

 

EP206/XV-8028

2.6

 

 

EP206/XV-13046

3.3

 

 

EP206/XV-13051

2.1

 

 

EP206/XV-13089

3.6

 

 

Installation

15

Page 27
Image 27
Emerson 400518-01 installation manual Installation, Drive/Motor Combination, Suggested KVA Rating