Emerson 400518-01 Diagnostics, Display, Fault, Action to Reset, Bridge Disabled

Models: 400518-01

1 88
Download 88 pages 22.24 Kb
Page 55
Image 55
Display

Safety Information

Product Overview

Installation

Diagnostics

Options and Accessories

Specification

The +/- Travel Limit faults are automatically cleared when the fault condition is removed. The table below lists all the fault codes in priority order from highest to lowest. This means that if two faults are active, only the higher priority fault will be displayed.

Display

Fault

Action to Reset

Bridge Disabled

 

Flash Invalid

Reprogram the Flash

Yes

 

 

 

 

 

Drive Power Up Test

Cycle Logic Power

Yes

 

 

 

 

 

NVM Invalid

Reset Button or Input Line

Yes

 

 

 

 

 

Invalid Configuration

Reset Button or Input Line

Yes

 

 

 

 

 

Drive Overtemp

Allow Drive to cool down,

Yes

 

Cycle Logic Power

 

 

 

 

 

 

 

 

Power Module

Reset Button or Input Line

Yes

 

 

 

 

 

High DC Bus

Reset Button or Input Line

Yes

 

 

 

 

 

Low DC Bus

Reset Button or Input Line

Yes

 

 

 

 

 

 

Reset Button or Input Line on EP-P drive

 

 

Encoder State

and

Yes

 

 

Cycle Logic Power on the other models

 

 

 

 

 

 

 

Reset Button or Input Line on EP-P drive

 

 

Encoder Hardware

and

Yes

 

 

Cycle Logic Power on the other models

 

 

 

 

 

Diagnostics and Troubleshooting

43

Page 55