Epsilon Eb Digital Servo Drive Installation Manual

Figure 35: Drive Faults Detected Dialog Box

Resetting Faults

Some drive faults are automatically reset when the fault condition is cleared. Others require drive power to be cycled or the drive to be “rebooted” to be cleared. If you wish to continue working in the PowerTools software without resetting the fault, click the Ignore Fault button.

To reset faults that can be reset with the Reset Faults button, simply click the Reset Faults button in the Drive Faults Detected dialog box or push the Reset button on the front of the drive where the fault occurred.

Viewing Active Drive Faults

To view all active drive faults, select the View Faults command from the Device menu. The dialog box displayed is the same as Active Drive Faults dialog box described above.

Rebooting the Drive

To reboot the drive, cycle power or select the Reboot Drive command from the Device menu. This command reboots the drive attached to the active Configuration Window.

Watch Window

This feature allows you to customize a window to monitor drive parameters which you select from a complete list of drive parameters. From this window you can watch the parameters you selected in real time. This feature is only available when you are online with the drive.

Note

You cannot change the values of the parameters while they are being displayed in the Watch Window. The parameter in the setup screens will look like they have been changed when they actually have not. To update a parameter, delete it from the Watch Window selection.