Epsilon Eb Digital Servo Drive Installation Manual

Cable to Enclosure Shielding

Shielded motor, feedback, serial communications, and external encoder cables were used for Control Technicques’ compliance testing and are necessary to meet the EMC requirements. Each cable shield was grounded at the enclosure wall by the type of grommet described earlier and shown in the figure below.

Figure 2:

Through Wall Shield Grommet

 

 

 

 

 

 

 

Cable Type

Control Techniques

Shielded Cable

Conduit Dimension

Actual Hole Size

Cable Model

Grommet Kit Part #

Hole Size

 

 

Motor Cable, 16 Ga

CMDS

CGS-050

1/2" pipe

7/8"

 

 

 

 

 

Motor Cable, 12 Ga

CMMS

CGS-050

1/2" pipe

7/8"

 

 

 

 

 

Feedback Cable

CFOS

CGS-050

1/2" pipe

7/8"

 

 

 

 

 

Flex Motor Cable, 16 Ga

CMDF

CGS-050

1/2" pipe

7/8"

 

 

 

 

 

Flex Motor Cable, 12 Ga

CMMF

CGS-075

3/4" pipe

1 1/16"

 

 

 

 

 

Flex Feedback Cable

CFCF, CFOF

CGS-063

3/4" pipe

1 1/16"

 

 

 

 

 

External Encoder

ENCO

CGS-038

1/2" pipe

7/8"

 

 

 

 

 

AC Power

user supplied

user supplied

 

 

 

 

 

 

 