Emerson 400501-05 View Motor Parameters, Group, Clear All Button, Save Selections Button

Models: 400501-05 Epsilon Eb Digital Servo Drive

1 100
Download 100 pages 2.92 Kb
Page 60
Image 60
Group

Epsilon Eb Digital Servo Drive Installation Manual

Group

This list box enables you to view the complete list of parameters or just a group of parameters you are interested in. The groups include:

 

Analog Out

Fault Log

Setup

 

 

 

 

 

 

 

Communication

Home (FM-2 / Ei only)

Status

 

 

 

 

 

 

 

Digital Inputs

ID

Torque

 

 

 

 

 

 

 

Digital Outputs

Index (FM-2 / Ei only)

Tuning

 

 

 

 

 

 

 

Execution

Motor

User Def Motor

 

 

 

 

 

 

 

Fault Counts

Position

Velocity

 

 

 

 

 

 

 

 

 

 

 

Clear All Button

This button is used to clear all the parameter selections that were previously selected.

Save Selections Button

This button saves the parameter selections. This enables you to restore the same list of parameters for use in future online sessions.

Restore Selections Button

This button restores the parameter selections previously saved. This enables you to restore the list of parameters you created in a previous online session.

View Motor Parameters

When online with the drive this feature allows you to display a pre-defined Watch Window to monitor three motor parameters. These parameters are normally used when testing the setup of a User Defined Motor for commutation accuracy.

Figure 38: View Motor Parameters Window

The View Motor Parameters window is accessed by selecting View Motor Parameters from the Tools menu.