Epsilon Eb Digital Servo Drive Installation Manual

Travel Limit +/-

This fault is caused when either the + or - Travel Limit input function is active.

“All On”

This is a normal condition during power up of the drive. It will last for less than 1 second. If this display persists, call Control Techniques for service advice.

Normally, “All On” appears for less than one second during power-up. All segments are dimly lit when power is “Off.” This is normal when an external signal is applied to the encoder inputs (motor or master) or serial port from an externally powered device. The signals applied to the inputs cannot exceed 5.5V level required to drive logic common or drive damage will occur.

Diagnostic Analog Output Test Points

The drive has two 8-bit real-time analog outputs which may be used for diagnostics, monitoring or control purposes. These outputs are referred to as Channel 1 and Channel 2. They can be accessed from the Command Connector on the drive or from the Diagnostics Analog Output Pins located on the front of the drive.

Each Channel can be programmed to the following sources:

Analog Output Source options

Velocity Command

Velocity Feedback

Torque Command (equates to Torque Command Actual parameter)

Torque Feedback

Following Error

Default Analog Output Source

Channel 1 = Velocity Feedback

Channel 2 = Torque Command

Output

Source

Offset

Scale

1

Velocity Feedback

0

600 RPM/volt

 

 

 

 

2

Torque Command

0

30 percent/volt for selected

motor

 

 

 

 

 

 

 

The DGNE cable was designed to be used with either an oscilloscope or a meter. The wires are different lengths to avoid shorting to each other. However, if signals do get shorted to GND, the drive will not be damaged because the circuitry is protected.

38

Page 56
Image 56
Emerson 400501-05, Epsilon Eb Digital Servo Drive Diagnostic Analog Output Test Points, Output Source Offset Scale