Soundolier AA35 Zone 2 Output Connector, Zone 2 Output Level Control, Mute Sensitivity Control

Models: AA35

1 24
Download 24 pages 60.34 Kb
Page 9
Image 9

AA35 MIXER AMPLIFIER

OWNER'S MANUAL

17

13

Unswitched Outlet

Outlet Breaker

Pre Out Line Out A

Input 3

Input 2

120V AC 60Hz

125V AC 4A

 

 

 

Max 500W

Push Reset

 

 

 

LL

77)+

7jbWiIekdZ77I[h_[iC_n[h7 fb_\_[h

1

2

3

4

5

6

7

8

Zone 2 Assign

Mute Rcv

Phantom

Input1

Low cut

Input 3

Input 2

Input 1

Input 3

Input 2

 

 

 

Off

Off

Off

Off

Off

Off

Line/Tel

Off

On

On

On

On

On

On

Mic

On

 

R

R

 

Amp In

Line Out B

 

 

 

 

Zone 2 Out

Speaker Output 35W

1W

 

 

 

8

600

COM 8

25V 70V

- +

- +

Zone2Mute

0

10

0

10

Level

 

Sens

Remote

 

 

 

Mute

Input 1

 

 

 

G -

+

 

16

15

120V AC 60Hz 100W

CLASS 2 WIRING

 

£Èä£Ê>VŽÊV>ÞÊ Û`°]ʘ˜ˆÃ]Ê/8ÊÇx££™Ê

 

­nää®ÊnÇȇÎÎÎÎÊ̏>Ã-œÕ˜`°Vœ“

14

13.Input 3

Input 3 consists of stereo summing inputs, suitable for connection to the output of CD/DVD players, etc.

14.Zone 2 Output Connector

Use the 1W 8Ω terminals for connection to an external speaker. The 600Ω 1.5V output is typically connected to a PBX music on hold port, also known as MOH.

15.Zone 2 Output Level Control

This rotary control will vary the signal level at the Zone 2 output terminals. Fully counter-clockwise (0) is off, fully clockwise (10) is the maximum output level. The Zone 2 level control is PRE Inputs 1, 2, and 3 volume controls.

16.Mute Sensitivity Control

VOX Mute Sensitivity Control adjusts how sensitive the mute send circuitry on Input 1 reacts. Setting the control fully counter-clockwise will lower the sensitivity, where a higher amplitude signal will be required at Input 1 to trigger the mute send circuits. Fully clockwise will raise the sensitivity of the mute circuits, where a lower amplitude signal will trigger a mute send. Careful calibration of this control may be required to fully utilize the mute circuits capabilities.

17.Line Out A/B

Line Out connectors A/B are paralleled jacks and are useful for providing unbalanced line level signal to another amplifier or other external devices. Prior to using this feature one must understand where the internal signal pick up point is so you can decide if it is correct for your application. We suggest you refer to the block diagram of the AA35 to have a complete understanding of the signal flow.

Note The Following Conditions For Line Out A/B

A. Post Low Cut Filter and is affected when filter is engaged.

B. Post Tone Controls (meaning the settings for the Bass and Treble controls affect this signal output). Note: Refer to Low Cut Filter Switch for complete understanding of the LCF feature.

C. Post Amp In (meaning any signal that is inserted into the Pre AMP In jack will be present at the Line Out A and B).

Specifications are subject to change without notice

AtlasSound.com

1601 JACK MCKAY BOULEVARD ENNIS, TEXAS 75119 U.S.A. •

TELEPHONE: (800) 876-3333

FAX: (800) 765-3435

©2006 ATLAS SOUND LP

Printed in U.S.A.

000106

ATS002171 RevA 01/06

PP

 

 

 

 

9

Page 9
Image 9
Soundolier AA35 specifications Zone 2 Output Connector, Zone 2 Output Level Control, Mute Sensitivity Control, Line Out A/B