WIRING

POWER AND GROUND

To ensure maximum output from your RUBICON amplifier, use high quality, low- loss power and ground cables and connections. The RUBICON amplifiers will accept up to 4 gauge power and ground cables. Determine from the chart below the minimum gauge power and ground wire for your application.

 

 

up to 70’

 

up to 20’

 

 

 

 

 

RUB/CON 507/

1

4 or 8 gauge

I

4 gauge only

 

 

 

 

 

CIRCUIT BREAKERS AND FUSES

EXTERNAL

Like all audio components, the RUBICON amplifiers must be fused near the batters. A fuse or circuit breaker must be located within 18” of the batterv. This will

e

*

prevent a fire in the event of a shorted cable. See the chart below to determine the correct fuse value.

INTERNAL

The RUBICON amplifiers are fused with an automotive-type or Maxi-fuse. In the event of a blown power supply fuse(s), replace with the correct value fuse found in the chart below. Never replace the fuse with a higher value than what is sup- plied. This may result in amplifier damage and will void the warranty!

RUB/CON Amplifier Fuse Values

Battery Fuse / Circuit

Amplifier Fuse

Breaker

1 RUB/CON 507/ 1
(2) 30 amp automotive

I

80 amp

 

 

 

11