TRIDENT PROTECTION CIRCUITRY
Your Rubicon amplifier is protected against both overheating and short circuits by means of main power fuses and the following circuits:
+Speaker Output Protection
+Ground Fault Differential
+Smart Power Supply Thermal Rollback & a Thermal Protection Circuit
NOTE: If you experience blown main power supply fuses, if is like$ that the amplifier is seeing a dead short, either in the speaker wire or in the speaker itself. Rectify the problem before b/owing mu/tip/e fuses! DO NOT increase values beyond the original fuse value! Doing so will void your warrant and may damage your amplifer.
TROUBLESHOOTING
PROBLEM | CAUSE | |
|
| |
| 1. No power or ground at the | |
No Sound and power LED is not | amp. | |
lit | 2. No remote | |
| 3. Blown fuse near the battery | |
|
| |
| 1. No signal input | |
No sound, power LED is lit. | 2. The AIRBASSkcessory | |
switch is in the “IN” position. | ||
| ||
| Move it to the “OUT’ position. | |
|
| |
Repeatedly blow amp fuse; | 1. Speaker or leads may be | |
shorted | ||
frequent activation of Smart | ||
2. Verify adequate amp | ||
Power Supply Circuit | ||
ventilation | ||
| ||
|
| |
| Output signal level is too high and | |
| the amplifier output is clipping. | |
“Clip” indicator lighting | Reduce the level either at the | |
| source or at the input level | |
| controls. | |
|
|
15