TRIDENT PROTECTION CIRCUITRY

TRIDENT PROTECTION CIRCUITRY

Your Rubicon amplifier is protected against both overheating and short circuits by means of main power fuses and the following circuits:

+Speaker Output Protection

+Ground Fault Differential

+Smart Power Supply Thermal Rollback & a Thermal Protection Circuit

TROUBLESHOOTING NOTE: If you experience blown main power supply fuses, if is like$ that the amplifier is seeing a dead short, either in the speaker wire or in the speaker itself. Rectify the problem before b/owing mu/tip/e fuses! DO NOT increase values beyond the original fuse value! Doing so will void your warrant and may damage your amplifer.

TROUBLESHOOTING

PROBLEM

CAUSE

 

 

 

1. No power or ground at the

No Sound and power LED is not

amp.

lit

2. No remote turn-on signal

 

3. Blown fuse near the battery

 

 

 

1. No signal input

No sound, power LED is lit.

2. The AIRBASSkcessory

switch is in the “IN” position.

 

 

Move it to the “OUT’ position.

 

 

Repeatedly blow amp fuse;

1. Speaker or leads may be

shorted

frequent activation of Smart

2. Verify adequate amp

Power Supply Circuit

ventilation

 

 

 

 

Output signal level is too high and

 

the amplifier output is clipping.

“Clip” indicator lighting

Reduce the level either at the

 

source or at the input level

 

controls.

 

 