Chapter 3. Configuring the Library
28
Before setting the emulation mode for the library robotics or tape drives, find the
setting you want to use in the table below.
Emulation Mode Switch Setting
Response to the Inquiry Command Drive DIP
Switch
Settinga
a. The Drive DIP Switch (default 0) determines the drive emulation and is set electronically by the configuration switch.
Library Inquiry
Drive
Manufacturer
Drive
Model
Default—
random access
0 Spectra 215 Sony SDX-300C
SDX-500C
SDX-700C
0
Tape stacker mode—Drive
1 only,
no random access robotics
commands
1No change
b
b. Values listed "No change" retain the last setting; it may be necessary to set the configuration switch a second time.
No changebNo changebNo changeb
Spectra 10000 library
emulation
2 Spectra 10000 No changebNo changebNo changeb
Exabyte EXB 210 library
emulation
3 Exabyte EXB-210 Exabyte EXB-8900 No changeb
HP 9000 Model 700/800
(GSC Controller) emulation
ANo change
bHewlett Packard C-1533A 13
Quantum DLT-7000 drive
emulation
BNo change
bQuantum DLT-7000 No changeb
Custom (AIT-2 only) C No changebSony SDX-300C No changeb
StorageTek 9490 drive
emulation
DNo change
bSTK 9490 No changeb
Spectra 4000 library emu-
lation
E Spectra 4000 No change No change No changeb
User-defined emulation F Use the serial cable to change these settings