| SYSTEM SPECIFICATIONS |
|
Sediment | 0.5 micron MicroTec™ sediment | |
Carbon Filter | 0.5 micron carbon block | |
RO Membrane Type | ||
DI Cartridges | MAXCAP DI ™ | |
| SilicaBuster™ DI | |
Rejection Rate | Greater than 98% average | |
Input Water Pressure | 60 psi (4.15 bar) line pressure* | |
Input Water Temp | 77°F (25°C) | |
Recovery Rate | 20% (i.e. 20% of the water will be | |
| collected as pure water) |
Nominal Membrane Flow Rates @ 60 psi & 77° F : |
| |
GPD (lpd) | Product Water Flow Rate | Concentrate Flow Rate |
90 (340) | 235ml/min | 940 ml/min |
150 (340) | 235ml/min | 940 ml/min |
300 (680) | 470ml/min | 1880 ml/min |
Reverse Osmosis Membrane Feed Water Requirements
For the 1 year SpectraSelect TFC membrane
Operating Pressure* | 40 – 80 psi (2.75 – 5.5 bar) |
pH Range | 3 – 11 |
Maximum Temperature | 100° F (38° C) |
Maximum Turbidity | 1.0 NTU |
Maximum Silt Density Index | 5.0 (based on 15 min. test time) |
Maximum Chlorine | less than 0.1 ppm |
Maximum TDS | 2000 ppm |
Maximum Hardness | 10 grains (170 ppm as CaCO3) |
Maximum Iron | less than 0.1 ppm |
Maximum Manganese | less than 0.1 ppm |
Maximum Hydrogen Sulfide | 0 ppm |
Langlier Saturation Index | LSI must be negative |
*Operating pressure less than 40 psi will require a booster pump:
less than 49 GPD use
*Operating pressure greater than 80 psi will require a pressure reducing valve.
| SpectraPure®Inc. 480.894.5437 Call us |
4 | 2167 East Fifth St, Tempe, Arizona 85281 |
|
SpectraPure®
TESTING THE PERFORMANCE OF THE MEMBRANE
Membrane Output Calculation
Membranes produce the rated gallons per day (GPD) at 60 psi (4.1 bars) operat- ing pressure, 77°F (25°C) operating temperature and 500 ppm total dissolved solids.
Membrane output gallons per day (GPD) depends on operating pressure, water temperature and the ppm TDS in the feed water.
Expected GPD = Rated GPD × PCF × TCF
PCF is the pressure correction factor
TCF is the temperature correction factor
Calculation of Pressure Correction Factor (PCF): The output (GPD) from the membrane is directly proportional to the applied pressure.
Note: The membrane is rated to produce the rated GPD at 60 psi. For any pres- sure other than 60 psi the output GPD is multipled by the PCF.
PCF = Line Pressure (in psi) ÷ 60
Calculation of Temperature Correction Factor (TCF): The output (GPD) also decreases with decrease in temperature. This is because water viscosity increases with decrease in water temperature.
Temperature Correction Factor Table (TCF)
°F /°C | TCF | °F \°C | TCF | °F \°C | TCF | |
41.0 | /5 | 0.521 | 59.0 /15 | 0.730 | 77.0 /25 | 1.000 |
42.8 | /6 | 0.540 | 60.8 /16 | 0.754 | 78.8 /26 | 1.031 |
44.6 | /7 | 0.560 | 62.6 /17 | 0.779 | 80.6 /27 | 1.063 |
46.4 | /8 | 0.578 | 64.4 /18 | 0.804 | 82.4 /28 | 1.094 |
48.2 | /9 | 0.598 | 66.2 /19 | 0.830 | 84.2 /29 | 1.127 |
50.0 | /10 | 0.620 | 68.0 /20 | 0.857 | 86.0 /30 | 1.161 |
51.8 | /11 | 0.640 | 69.8 /21 | 0.884 | 87.8 /31 | 1.196 |
53.6 | /12 | 0.661 | 71.6 /22 | 0.912 | 89.6 /32 | 1.232 |
55.4 | /13 | 0.684 | 73.4 /23 | 0.941 | 91.4 /33 | 1.267 |
57.2/14 | 0.707 | 75.2 /24 | 0.970 | 93.2 /34 | 1.304 |
SpectraPure®Inc. Fax 480.894.6109 Fax us