ELECTRICAL PRECAUTIONS

Table 2 – Minimum approach distances to energized conductors for persons other than qualified line-clearance arborists and qualified line-clearance ar- borist trainees.

Nominal Voltage

Distance

 

kV phase-to-phase1

 

 

 

ft-in

 

m

 

 

0.0 to 1.0

10–00

 

3.05

1.1 to 15.0

10–00

 

3.05

15.1 to 36.0

10–00

 

3.05

36.1 to 50.0

10–00

 

3.05

50.1 to 72.5

10–09

 

3.28

72.6 to 121.0

12–04

 

3.76

138.0 to 145.0

13–02

 

4.00

161.0 to 169.0

14–00

 

4.24

230.0 to 242.0

16–05

 

4.97

345.0 to 362.0

20–05

 

6.17

500.0 to 550.0

26–08

 

8.05

785.0 to 800.0

35–00

 

10.55

1 Exceeds phase-to-ground.

The tie-in position should be above the work area and located in such a way that a slip would swing the arborist away from any energized electrical conductors or other identified hazard.

While climbing, the arborist should climb on the side of the tree that is away from energized electrical conduc- tors as required in Tables 1 and 2.

Footwear, including lineman’s overshoes, having electri- cal-resistant soles, shall not be considered as providing any measure of safety from electrical hazards.

Rubber gloves, with or without leather or other protec- tive covering, shall not be considered as providing any measure of safety from electrical hazards.

Ladders, platforms and aerial devices, including insulat- ed aerial devices, shall be subject to minimum approach distances in Table 1 and 2.

Aerial devices and attached equipment (such as chip- pers) contacting energized electrical conductors shall be considered energized. Contact shall be avoided, except where emergency rescue procedures are being carried out. Emergency rescue should be performed in accor- dance with 4.3.

STORM WORK AND EMERGENCY CONDITIONS-LINE CLEARANCE

Line clearance shall not be performed during adverse weather conditions such as thunderstorms, high winds and snow and ice storms.

Qualified line-clearance arborists and qualified line- clearance arborists trainees performing line clearance in the aftermath of a storm or under similar conditions shall be trained in the special hazards associated with this type of work.

Line-clearance operations shall be suspended when storm work or emergency conditions develop involving energized electrical conductors. Electrical system own- ers/operators shall be notified immediately.

8 ► CS05/CS06 User Manual

Page 8
Image 8
Stanley Black & Decker CS05/CS06 user manual Storm Work and Emergency CONDITIONS-LINE Clearance

CS05/CS06 specifications

Stanley Black & Decker has long been synonymous with quality and innovation in the industrial tools sector, and their CS05 and CS06 models exemplify this commitment. These two models represent some of the latest advancements in battery-powered electric tools designed for both professionals and DIY enthusiasts.

The Stanley Black & Decker CS05/CS06 models are engineered with a powerful motor that delivers impressive torque and speed, allowing users to tackle a variety of tasks with ease. The CS05 model typically features a 20V Max lithium battery system that provides longer run time and improved battery life, ensuring that users can complete their projects without interruption. This battery technology is particularly advantageous for high-demand applications, making it ideal for construction, woodworking, and metalworking.

One of the standout features of the CS05/CS06 is their ergonomic design. Both models boast a lightweight structure and well-balanced form, allowing for extended use without causing fatigue. The soft-grip handle enhances user comfort and control, making precision tasks much simpler. Additionally, the compact design of the tools aids in maneuverability in tight spaces, making them perfect for both professional and home environments.

In terms of technology, the CS05/CS06 incorporates advanced electronic controls that offer variable speed settings. This allows users to adjust the speed according to the specific requirements of the job, providing versatility that is essential for tackling various materials and applications. The built-in LED work light is another handy feature, illuminating dark areas or work surfaces to improve visibility and accuracy during use.

Durability is a prominent characteristic of the Stanley Black & Decker CS05 and CS06 models. Constructed with high-quality materials, both tools are designed to withstand the rigors of demanding job sites. The protective housing and robust components ensure longevity and reliable performance, even under extreme conditions.

Lastly, both models come equipped with features that enhance safety, including safety switches and guards that prevent accidental starts. The overall combination of strength, versatility, comfort, and safety makes the Stanley Black & Decker CS05/CS06 a top choice for anyone looking to invest in a reliable, high-performance electric tool. In today's ever-evolving market, these models stand out as examples of where quality meets innovation.