QUICK DISCONNECT COUPLERS
H.T.M.A. approved quick disconnect couplings are installed to hydraulic hoses so that the direction of oil flow is always from the male to the female quick disconnect as shown in figure 2. Quick disconnect couplings and hose fittings are selected so that additional fittings such as reducer or adapt- er fittings are not required.
If adapter fittings are used, they must be approved steel hydraulic fittings meeting a minimum operating pressure rating of 2500 psi/172 bar. Do not use galvanized pipe fit- tings or black pipe fittings.
Use thread tape or pipe joint compound when installing quick disconnect couplings to hose or tool fittings. Follow the instructions furnished with the selected thread sealant.
DO NOT OVERTIGHTEN THE FITTINGS.
6. BATTERY
NOTICE
Do not charge the battery with a standard automotive
battery charger. This type of charger produces a charging amperage higher than 2 amps. Charging the battery at higher than 2 amps will damage the battery.
NOTICE
If the engine runs out of gas or dies during operation
and the ignition switch is left in the ON or RUN position, this could drain the battery. Make sure the ignition switch is returned to the OFF position.
OPERATION
CONTROL PANEL
Figure 2
PRESSURERETURN
H.T.M.A. 1/2 INCH FE-
MALE QUICK DISCON-
NECT COUPLER
H.T.M.A. 1/2 INCH MALE
QUICK DISCONNECT
COUPLER
1/2 INCH MALE PIPE HOSE END
1/2 INCH I.D. HOSE, 25 FT LONG WITH 2500 PSI/ 172 BAR RATING AND
4 TO 1 SAFETY FACTOR
PRESSURERETURN
1/2 INCH MALE PIPE HOSE END
H.T.M.A. 1/2 INCH FE-
MALE QUICK DISCON-
NECT COUPLER
H.T.M.A. 1/2 INCH MALE
QUICK DISCONNECT
COUPLER
ADAPTER, 3/8 INCH MALE PIPE x
|
| TOOL |
|
|
PRESSURE |
|
| RETURN | |
|
|
|
|
|
|
|
|
|
|