Engine will not start.

Flow selector switch not in the

Make sure both flow selector switches

 

 

OFF position.

are in the OFF position when starting.

 

 

 

 

 

 

 

Battery not connected.

Attach battery cables, check wires.

 

 

 

 

 

 

 

Weak battery.

Test battery, charge or replace.

 

 

 

 

 

 

 

No fuel.

Add Fuel.

 

 

 

 

 

 

 

Fuel filter plugged.

Replace fuel filter.

 

 

 

 

 

 

 

Defective spark plugs.

Remove plugs, check gap, clean or

 

 

 

replace.

 

 

 

 

 

Fluid blowing out of fluid

 

 

 

reservoir vent.

Hydraulic tank overfilled.

Correct the fluid level.

 

 

 

 

 

 

 

Pump suction leak.

Check suction connections. Tighten if

 

 

 

necessary.

 

 

 

Hydraulic tool won't operate.

Flow selector switch not switched

Check that the flow selector switch

 

 

ON.

is set to 5 or 10 gpm.

 

 

 

 

 

 

 

Incorrect hose connection to

Make sure the tool hose circuit goes

 

 

tool.

from left (pressure) fitting to tool

 

 

 

and back to the right fitting (return).

 

 

 

Fluid always flows from the male to

 

 

 

female fittings.

 

 

 

 

 

 

 

Quick disconnect fittings

Detach from hose, connect set

 

 

defective.

together and check for free flow.

 

 

 

 

 

 

 

Hydraulic fluid level low.

Check for correct fluid level. Fill

 

 

 

using the recommended fluid.

 

 

 

 

 

 

 

Pump coupling defective.

With the engine not running.

 

 

 

Check the coupling between the pump

 

 

 

and engine that it is engaged and is

 

 

 

not damaged. Caution: Keep hands

 

 

 

clear of rotating objects.

 

 

 

 

 

 

 

Relief valve stuck open.

Adjust or replace valve.

 

 

 

 

 

 

 

Suction hose kinked.

Make sure suction hose from fluid

 

 

 

reservoir to pump inlet has a smooth

 

 

 

curve.

 

 

 

 

 

 

 

Solenoid not working.

Check solenoid operation and electrical

 

 

 

connections.

 

 

 

 

 

 

Tool is defective.

Refer to tool manual.

 

 

 

 

 

 

 

 

 

 