Troubleshooting

 

FLOW TEST PROCEDURE

Example:

 

Stabilized Temperature

160°

Ambient Temperature

-80°

Heat Rise

80°

The normal operating temperature range of this circuit will be the typical ambient temperature range for the geo- graphical area plus the heat rise calculated above. Ensure that the operating temperature range is lower than 180° for optimum operation of the attachment.

Troubleshooting

If adequate pump flow is available from the carrier pump(s) but is not getting to the attachment, consult your service representative and review the following:

1.Attachment valve(s) are not actuating. Review all elec- trical connections that are part of the attachment kit.

2.Ensure proper voltage to the valve(s).

3.Ensure the REG port of the valve is not blocked.

4.Check to make sure the carriers main relief is set to the manufacturers recommendation and that this value is equal or greater than the attachment circuit relief.

5.If the valve will not turn off, check the drain (tank) line of the valve to ensure that the pressure is 50 psi or less.

12 ► HSX User Manual