Stanley Black & Decker MB05 user manual Troubleshooting, Problem Cause Solution

Models: MB05

1 34
Download 34 pages 8.98 Kb
Page 15
Image 15

TROUBLESHOOTING

This section describes how to find and resolve problems users may experience. If a situation occurs that is not covered, call your Stanley Customer Service representative for assistance.

WARNING

Inspecting the tool or installing parts with the hydraulic hoses connected can result in severe personal injury or equipment damage. To prevent accidental startup, disconnect the hydraulic power before beginning any inspection or installation task.

If symptoms of poor performance develop, the following chart can be used as a guide to correct the problem.

When diagnosing faults in operation of the tool, always check that the hydraulic power source is supplying the correct hydraulic flow and pressure to the tool as listed in the table below. Use a flowmeter known to be accurate. Check the flow with the hydraulic oil temperature at least 80 °F/27 °C.

PROBLEM

CAUSE

SOLUTION

Breaker will not fire.

Low hydraulic oil level.

Fill reservoir.

 

No flow to breaker.

Have hydraulic circuit tested by

 

Main relief set low.

authorized dealer/distributor per

 

 

approved procedure.

 

Internal damage.

Have unit serviced by an authorized

 

 

dealer/distributor.

 

Damaged quick couplers.

Replace.

Breaker runs slowly.

Low hydraulic flow

Have hydraulic circuit tested by an

 

Excessive heat build up.

authorized dealer/distributor per

 

 

approved procedure.

 

Excessive nitrogen pressure.

Have unit serviced by an authorized

 

 

dealer/distributor.

 

Internal leakage.

Breaker runs erratically.

Low or excessive back-pressure.

Have carrier serviced by an

 

Damaged switch or connection.

authorized dealer/distributor.

 

Relief set too low.

 

 

Internal damage.

 

 

Tool binding.

Add grease to tool shank. Do not

 

 

pry while operating.

Breaker runs but at reduced power.

Low accumulator charge.

Have unit serviced by an authorized

 

Excessive back-pressure.

dealer/distributor.

 

Relief set too low.

 

Breaker leaks oil around tool bit and

Lower seals failed.

Have unit serviced by an authorized

tool bushing.

 

dealer/distributor.

Hydraulic system overheats.

Main relief set low.

Have unit serviced by an authorized

 

 

dealer/distributor.

 

Insufficient cooling capability in

 

hydraulic circuit.

 

 

Line/hose size too small.

 

 

Excessive back-pressure.

 

MB05 User Manual ◄ 15

Page 15
Image 15
Stanley Black & Decker MB05 user manual Troubleshooting, Problem Cause Solution