TROUBLESHOOTING

If symptoms of poor performance develop, the following chart can be used as a guide to correct the problem.

When diagnosing faults in operation of the spike puller, always check that the hydraulic power source is supplying the correct hydraulic flow and pressure to the spike driver as listed in the table. Use a flowmeter known to be ac- curate. Check the flow with the hydraulic oil temperature at least 80 °F/27 °C.

Problem

Cause

Solution

 

Hydraulic power source not functioning

Check power source for proper flow

 

and pressure (5-10 gpm/19-34 lpm,

 

correctly.

 

2500 psi/172 bar.

Spike puller does not cycle.

 

Coupler or hoses blocked.

Remove obstruction.

 

 

Pressure and return line hoses reversed

Be sure hoses are connected to their

 

at ports.

proper ports.

 

Hydraulic power source not functioning

Check power source for proper flow

 

and pressure (5-10 gpm/19-34 lpm,

 

correctly.

 

2500 psi/172 bar.

 

 

Spike puller does not pull effectively.

Couplers or hose blocked.

Remove restriction.

Fluid too hot (above 140 °F/60 °C).

Provide cooler to maintain proper fluid

 

 

temperature.

 

 

 

The jaw is not sliding freely in the

Remove, clean and replace as

 

chute.

required.

 

Low oil flow from power unit.

Check power source for proper flow

 

and oil level.

 

 

Spike puller operates slow.

 

Check hydraulic system for excessive

High back pressure.

back pressure and correct as

 

 

 

required.

 

Couplers or hoses blocked.

Remove obstruction.

Jaw re-tracked with tool in neutral

Pressure and return lines reversed at

Be sure hoses are connected to their

position

ports.

proper ports.

NOTICE

In addition to the Safety Precautions found in this manual, observe the following for equipment protection and care.

Always store an idle tool in a clean dry space, safe from damage or pilferage.

Do not exceed the rated limits or use the tool for ap- plications beyond its design capacity.

Always keep critical tool markings, such as labels and warning stickers legible.

Always replace hoses, couplings and other parts with replacement parts recommended by Stanley Hydraulic Tools. Supply hoses must have a mini- mum working pressure rating of 2500 psi/175 bar.

Permit only experienced personnel to perform tool repair.

Be sure to wipe all couplers clean before con­necting. Use only lint-free cloths.

The hydraulic circuit control valve must be in the OFF position when coupling or uncoupling the tool. Failure to do so may result in damage to the quick couplers and cause overheating of the hydraulic system.

Check fastener tightness often and before each use daily.