DESCRIPTION OF FUNCTIONS
FADER CLEANING AND REPLACEMENT
After constant scratch use the
PostScript Picture
Removing a fader:
1.Make sure mixer is powered off and power supply is disconnected from back of mixer.
2. To remove the lower faceplate, take off the 3 fader knobs and then remove the 4 screws located on the sides of the mixer (2 on each side). See Figure 1. Lift up on the faceplate and it will slide off.
3.Remove the fader to be cleaned or replaced by unscrewing the 2 outer screws on the fader plate (removing the 2 inner screws will detach the fader from the fader plate). See Figure 2.
4.Disconnect the fader from mixer by removing the 4- pin connector on the bottom of the fader.
Replacing a fader:
1.Once original fader has been removed, simply plug the
2.Set selector switch to position of fader you are using (P+G or Focus Fader). See Figure 3.
3.Place fader back in mixer and replace 2 outer screws to secure fader.
Cleaning a Penny & Giles fader:
1.Remove 2 mounting scews from faderplate. (NOTE: The P&G fader is designed with floating mounting threads for precise mechanical centralising of the fader. If you desire to keep your fader`s current mounting position we suggest that you make 2 marks on both ends of the fader on the fader plate to indicate the P&G fader posi -
tion.) See Figure 4.
2.Once fader is removed from unit,
remove the two screws (A) from
the end of the fader body where | A |
| |
the wires exit the fader casing. Pull |
|
away the end block. Withdraw the |
|
dust cover (B). Taking great care, |
|
Figure 3
BC
F
E
G
D