APPENDIX
A-4. Power supply
(1) AC Adaptor | |
(2) Input | 90 to 264V AC, 50/60Hz |
(3) Output | 24V DC ±5%, 2.0A |
(4) Plug | |
| equivalent.) |
Important!
•When using a printer power supply other than the optional AC adaptor
•Use a power supply of DC 24 V ±5% and more than 2.0 A.
•Be careful about installing the printer in an area where there is noise. Take the appropriate measures to protect against electrostatic AC line noise, etc.
•The optional cable set can be connected.
A-5. Environmental requirements
(1) Operating | 5°C to 40°C |
Temperature | |
Humidity | 10% to 85% |
(2) Transport/storage (when packed) | |
Temperature | |
Humidity | 5% to 95% |
Note: The maximum |
A-6. Reliability
(1) MCBF | 37.5 million lines |
(2) Printer life | 25 million lines |
(3) Print head life | 120 km (with designated paper) |
(4) Cutter life | 1.5 million cuttings (with designated paper) |
Operating conditions for above reliability
a)500 patterns/day
b)25 line feeds and 1 cut per pattern
c)Powered on for 10 hours per day
d)340 days/year
e)Print duty 16.5% or less