Star Trac TR 4500 manual = Unit was resetting

Models: TR 4500

1 105
Download 105 pages 53.37 Kb
Page 17
Image 17

Maintenance Mode

Parameters

Lowest

Highest

Option 1

Option 2

Default

Meaning

 

Value

Value

 

 

Value

 

LSTRES

0

2

---

---

0

Displays

 

 

 

 

 

 

1 = Unit was resetting

 

 

 

 

 

 

to 0%.

 

 

 

 

 

 

0 = Unit finished

 

 

 

 

 

 

resetting to 0% prior

 

 

 

 

 

 

to the display code.

LSTSSP

0

255

---

---

0

Displays the speed

 

 

 

 

 

 

prior to the display

 

 

 

 

 

 

code.

LSTPWM

0

255

---

---

0

Displays the PWM

 

 

 

 

 

 

number prior to the

 

 

 

 

 

 

display code.

LSTMSP

0

255

---

---

0

Display the actual

 

 

 

 

 

 

measured speed prior

 

 

 

 

 

 

to the display code.

LST TM

0

65355

---

---

0

Displays the elapsed

 

 

 

 

 

 

time, in seconds, prior

 

 

 

 

 

 

to the display code.

LSTDCK

0

65355

---

---

0

Number of miles when

 

 

 

 

 

 

the deck was last

 

 

 

 

 

 

waxed. After a 2000

 

 

 

 

 

 

mile (or 3000 KM)

 

 

 

 

 

 

difference, “REWAX

 

 

 

 

 

 

BELT” will scroll in the

 

 

 

 

 

 

display until “LST

 

 

 

 

 

 

DCK” miles are

 

 

 

 

 

 

updated.

LSTBLT

0

65355

---

---

---

Number of miles when

 

 

 

 

 

 

the last belt was

 

 

 

 

 

 

replaced.

3.7