FIGURE 23
Apply
FIGURE 24
Check the level or slope of the venting again, and adjust if required.
SLOPE
TOP VIEW
90° MAXIMUM BEND
FIGURE 26
CONDITION 2:
Where floor joists impede venting, a rise or drop to complete the vent termination is possible. All installations require 1 in. (25mm) clearance to combustibles.
Note:
A. The maximum horizontal vent length of 80 in. (2.03m) minus wall thickness should be considered when installing an offset vent arrangement.
B. Do not combine condition 1 (Figure 26) with condition 2 (Figure 27) in the same installation.
C. The maximum allowable drop from vent
| >1 in. (25mm) |
| |
>1 in. |
|
| |
(25mm) |
|
| |
| 7.25 in. |
| |
“H” | (184mm) | WALL 10 in. | |
MAX | |||
SEE | (254mm) (REF) | ||
| |||
CHART |
|
| |
| MODELS | RECOMMENDED | |
| MINIMUM “H” | ||
|
| ||
| 40 gal. | 68 in. (1.72m) | |
| 50 gal. | 76 in. (1.93m) | |
| 50 gal. | 76 in. (1.93m) | |
| 75 gal. | 76 in. (1.93m) |
FIGURE 27
FIGURE 25
OFFSET VENT ARRANGEMENT
CONDITION 1:
Where a straight vent arrangement is impossible, a horizontal 90 degree maximum bend can be made. Use the water heater casing outer diameter as a template to form the corrugated tube.
18