PROBLEM

 

POSSIBLE CAUSE(S)

 

CORRECTION

 

1.

Insufficient secondary air

1.

Provide ventilation to water heater. Check

 

 

 

 

flue way, flue baffle and burner

 

2.

Flue clogged

2.

Clean flue, locate source and correct

SLOW HOT WATER RECOV-

3.

Low gas pressure

3.

Check with gas utility company

4.

Improper calibration

4.

Replace gas control/thermostat

ERY

5.

Gas control/thermostat set too low

5.

Turn temperature dial to desired setting

 

 

6.

Water heater too small

6.

Install adequate size heater

 

7.

Wrong piping connections

7.

Correct piping-dip tube must be in cold inlet

 

8.

Wasted hot water

8.

Advise customer

 

1.

Excessive water pressure

1.

Use a pressure reducing valve and relief

 

 

 

 

valve

DRIP FROM RELIEF VALVE

2.

Heater stacking

2.

Lower the thermostat setting

 

3.

Closed water system

3.

See “Closed System/Thermal Expansion”

 

4.

Temperature setting too high

4.

Decrease the temperature setting

THERMOSTAT FAILS TO

1.

Defective gas control/thermostat

1.

Replace gas control/thermostat

SHUT OFF

2.

Improper calibration

2.

Replace gas control/thermostat

 

1.

Insufficient secondary air

1.

Provide ventilation to water heater. Check

COMBUSTION ODORS

 

 

 

flue way, flue baffle, burner

2.

Flue clogged

2.

Clean, locate source and correct

 

 

3.

Heater installed in a confined area

3.

Provide fresh air ventilation

 

1.

Insufficient secondary air

1.

Provide ventilation to water heater. Check

 

 

 

 

flue way, flue baffle, burner

SMOKING AND CARBON

2.

Low gas pressure

2.

Check with gas utility company

3.

Flue clogged

3.

Clean, locate source and correct

FORMATION (SOOTING)

4.

Defective gas control/thermostat

4.

Replace gas control/thermostat

 

 

5.

Heater installed in a confined area

5.

Provide fresh air ventilation

 

6.

Burner flame yellow-lazy

6.

See “Burner Flame Yellow-Lazy”

CONDENSATION

1.

Temperature setting too low

1.

Increase the temperature setting

2.

Water heater too small

2.

Install adequate size heater

 

 

1.

Orifice too large

1.

Replace with correct orifice

BURNER FLAME FLOATS

2.

High gas pressure

2.

Check with gas utility company

3.

Flue clogged

3.

Clean flue and burner-locate source & cor-

AND LIFTS OFF PORTS

 

 

 

rect

 

 

 

 

 

4.

Cold drafts

4.

Locate source and correct

BURNER FLAME TOO HIGH

1.

Orifice too large

1.

Replace with correct orifice

 

1.

Defective gas control/thermostat

1.

Replace gas control/thermostat

FLAME BURNS AT ORIFICE

2.

Low gas pressure

2.

Check with gas utility company

 

3

Orifice not properly installed

3

Reinstall the orifice

28

Page 28
Image 28
State Industries 186589-001 Slow HOT Water Recov, Ery, Drip from Relief Valve, Thermostat Fails to, Shut OFF

186589-001 specifications

State Industries 186589-001 is a highly efficient water heater designed to meet both residential and commercial hot water demands. Known for its durability and exceptional performance, this unit is a popular choice among homeowners and business owners alike.

One of the standout features of the State Industries 186589-001 is its robust construction. The tank is made from high-quality materials that offer superior insulation, reducing heat loss and improving overall energy efficiency. This ensures a longer lifespan for the unit while minimizing operating costs. The model also features a glass-lined tank, which prevents corrosion and extends the longevity of the water heater.

The 186589-001 employs innovative heating technologies, including an advanced control system that provides precise temperature regulation. This allows users to set their desired water temperature easily, ensuring optimal comfort and safety. With a powerful heating element, the water heater can quickly heat water to desired levels, providing a reliable supply for various applications, from daily bathing to commercial needs.

Furthermore, the State Industries water heater is equipped with multiple safety features. An automatic shut-off function is integrated to protect against overheating, ensuring user safety during operation. Additionally, the model comes with a pressure relief valve, preventing potential hazards from excessive pressure build-up.

In terms of energy efficiency, the 186589-001 meets and often exceeds current industry standards. Its design minimizes energy consumption, which not only lowers utility bills for users but also aligns with environmentally sustainable practices.

The unit is designed for easy installation, making it convenient for both professionals and DIY enthusiasts. Clear instructions are provided, and the compact size allows it to fit in tight spaces, an advantage for those with limited installation options.

Overall, the State Industries 186589-001 stands as a reliable choice for those seeking a quality water heater with excellent features, advanced technology, and safety characteristics. Its commitment to durability and efficiency makes it a valuable investment for anyone in need of consistent hot water supply.