State Industries 315466-000, 185244-004, GS6 50 YRVIT Condensate, Maximum and Minimum Vent Lengths

Models: GS6 50 YBVIT GS6 40 YRVIT GS6 50 YBVIT 2 GS6 40 YBVIT 2 315466-000 GS6 40 YBDS 185244-004 GS6 50 YRVIT

1 32
Download 32 pages 56.77 Kb
Page 16
Image 16

The unit may be vented horizontally through a wall or vertically through the roof. Pipe runs must be adequately supported along both vertical and horizontal runs as follows:

For Schedule 40, 2" PVC, ABS, Coex Cellular Core vent pipe: Every 3 feet (0.9 m).

For Schedule 40, 3" PVC, ABS, Coex Cellular Core vent pipe: Every 3.5 feet (1.1 m).

For Schedule 40, 4" PVC, ABS, Coex Cellular Core vent pipe: Every 4 feet (1.2 m).

For Schedule 40, 2" CPVC vent pipe: Every 5 feet (1.5 m).

For Schedule 40, 3" CPVC vent pipe: Every 6 feet (1.8 m).

For Schedule 40, 4" CPVC vent pipe: Every 6.5 feet (2.0 m).

It is imperative that the first hanger (or support) be located on the horizontal run immediately adjacent to the first 90-degree elbow from the vertical rise. Support method used should isolate the vent pipe from the floor joists or other structural members to prevent the transmission of noise and vibration. Do not support, pin, or otherwise secure the venting system in a way that restricts the normal thermal expansion and contraction of the chosen venting material.

If the water heater is being installed as a replacement for an existing power vented heater in pre-existing venting, a through inspection of the existing venting system must be performed prior to any installation work. Verify that the correct material as detailed above has been used, and that the minimum or maximum vent lengths and terminal location as detailed in this manual have been met. Carefully inspect the entire venting system for any signs of cracks or fractures, particularly at the joints between elbows and other fittings and the straight runs of vent pipe. Check the system for signs of sagging or other stresses in the joints as a result of misalignment of any components in the system. If any of these conditions are found, they must be corrected in accordance with the venting instructions in this manual before completing the installation and putting the water heater into service.

Except where instructed in this manual, the mixing of 2", 3" and 4" vent pipe is NOT ALLOWED. If 2" pipe is to be used, then a 2" to 3" bell reducer is recommended. Figure 15 shows the recommended location for the bell reducer. If the bell reducer is located at the rubber boot on the blower assembly, then a short section of 3" vent pipe needs to be installed in the rubber boot for proper connection of the 2" to 3" bell reducer. That length can be of the minimum length required for the connection.

If 4" pipe is to be used, then a 3" to 4" bell reducer is recommended. Figure 15 shows the recommended location for the bell reducer. If the bell reducer is located at the rubber boot on the blower assembly, then a short section of 3" vent pipe needs to be installed in the rubber boot for proper connection of the 3" to 4" bell reducer. That length can be of the minimum length required for the connection.

The 40,000, 50,000, 55,000 and 62,500 BTU units are supplied with a 2" Schedule 40 PVC 22.5° Vent Terminal. If you decide to vent with 3" or 4" pipe, a Schedule 40 DWV 45° Vent Terminal must be used. For your convenience, we have included a screen for both 3" and 4" Vent Terminals.

The vent piping should be connected to the blower with a rubber adapter and secured with hose clamps. The adapter and clamps are provided with the heater.

Even the flue gas temperature leaving the blower is between 140°F (69°C) and 175°F (79°C), some installations will have water

condensate in the vent piping. If this occurs, then adequate means of draining and disposing of the condensate needs to be made by the installer.

CONDENSATE

Condensate formation does not occur in all installations of power vented water heaters, but should be protected against on installations where it can form in the venting system. Condensation in the venting system of power vented water heaters is dependent upon installation conditions including, but not limited to ambient temperature and humidity of installation location, ambient temperature and humidity of venting space, vent discharge and slope, and product usage. In certain conditions, installations in unconditioned space or having long horizontal or vertical vent runs may accumulate condensate. In these conditions, the vent pipe should be sloped downward away from the blower assembly 1/4" (6.4 mm) per five feet (1.5 m) of pipe but not more than 1 1/2" (3.8 cm) in the total vent length. If the vent piping is vented level or sloped upwards away from the blower assembly, then adequate means for draining and disposing of the condensate needs to be made by the installer (if condensate is detected). If you have condensate, then a 3/8" drain hose can be connected to the built-in drain port of the rubber boot on the blower assembly. For your convenience, the rubber boot is supplied with a removable cap on the built-in drain port. Prior to operating the water heater, make sure the removable cap is installed on the drain port (if a drain hose is not needed).

MAXIMUM AND MINIMUM VENT LENGTHS

40,000 BTU Units:

For 2" Venting, the maximum equivalent feet of pipe allowed is 40 feet (12.2 m). This does not include the supplied vent termination for the water heater. For the 2" venting, one 90° elbow is approximately equal to 5 feet (1.5 m). One 45° elbow is approximately equal to 2.5 feet (0.8 m). It is recommended that at least 2 feet (0.6 m) of spacing be used in between all 45° elbows and all 90°elbows.

For 3" Venting, the maximum equivalent feet of pipe allowed is 120 feet (36.6 m). This does not include the Vent Termination (supplied locally) for the water heater. For the 3" venting, one 90° elbow is approximately equal to 5 feet (1.5 m). One 45° elbow is approximately equal to 2.5 feet (0.8 m). It is recommended that at least 2 feet (0.6 m) of spacing be used in between all 45° elbows and all 90°elbows.

For 4" Venting, the maximum equivalent feet of pipe allowed is 160 feet (48.8 m). This does not include the Vent Termination (supplied locally) for the water heater. For the 4" venting, one 90° elbow is approximately equal to 8 feet (2.4 m). One 45° elbow is approximately equal to 4 feet (1.2 m). It is recommended that at least 2 feet (0.6 m) of spacing be used in between all 45° elbows and all 90°elbows.

50,000 BTU Units:

For 2" Venting, the maximum equivalent feet of pipe allowed is 40 feet (12.2 m). This does not include the supplied Vent Termination for the water heater. For the 2" venting, one 90° elbow is approximately equal to 5 feet (1.5 m). One 45° elbow is approximately equal to 2.5 feet (0.8 m). It is recommended that at least 2 feet (0.6 m) of spacing be used in between all 45° elbows and all 90°elbows.

For 3" Venting, the maximum equivalent feet of pipe allowed is 120 feet (36.6 m). This does not include the Vent Termination (supplied locally) for the water heater. For the 3" venting, one 90° elbow is approximately equal to 5 feet (1.5 m). One 45° elbow is approximately equal to 2.5 feet (0.8 m). It is recommended that at least 2 feet (0.6 m) of spacing be used in between all 45° elbows and all 90°elbows.

16

Page 16
Image 16
State Industries 315466-000, 185244-004, GS6 50 YRVIT, GS6 50 YBVIT 2 Condensate, Maximum and Minimum Vent Lengths

GS6 50 YBVIT, GS6 40 YRVIT, GS6 50 YBVIT 2, GS6 40 YBVIT 2, 315466-000 specifications

State Industries manufactures a variety of high-efficiency water heaters, including the GS6 models, which are designed to meet diverse residential and commercial needs. Among these, the GS6 50 YRVIT, GS6 40 YBDS, and GS6 40 YBVIT 2 stand out for their performance, advanced technologies, and distinctive features.

The GS6 50 YRVIT is a powerful 50-gallon gas water heater that boasts a 40,000 BTU input. This model is designed with a high-efficiency rating, enabling it to deliver a strong hot water supply while minimizing energy costs. Its glass-lined tank provides superior protection against rust and corrosion, ensuring durability and extending the lifespan of the unit. This model also features an innovative flue design that maximizes combustion efficiency, making it an environmentally friendly choice that adheres to stringent energy regulations.

The GS6 40 YBDS, on the other hand, is a more compact 40-gallon gas water heater, also with a 40,000 BTU input. This unit is particularly popular for smaller households or commercial spaces where space is limited. It also incorporates advanced technology to optimize performance while remaining user-friendly. The GS6 40 YBDS is equipped with a direct vent system, allowing for flexible installation options, ensuring that high-efficiency heating is available even in confined areas.

Lastly, the GS6 40 YBVIT 2 model takes energy efficiency a step further with its cutting-edge insulation system and advanced temperature control features. This 40-gallon water heater is specifically engineered to minimize heat loss, which translates into reduced energy expenses for the user. The stainless steel burner and exceptional venting design contribute to efficient hot water production, making the GS6 40 YBVIT 2 a reliable choice for families seeking consistent performance.

Across all GS6 models, State Industries emphasizes safety and reliability. Each unit includes several built-in safety features, such as a temperature and pressure relief valve and a flame arrestor to prevent flammable vapors from entering the burner. Moreover, the easy-to-use digital display allows users to monitor settings effortlessly.

In summary, the State Industries GS6 series, including the GS6 50 YRVIT, GS6 40 YBDS, and GS6 40 YBVIT 2, combines efficiency, cost-effectiveness, and advanced technologies, catering to the hot water needs of any home or business. With their robust construction and innovative features, these water heaters provide dependable service and peace of mind to users.