General Safety (cont’d)

WARNING

This water heater must not be installed directly on carpeting. Car- peting must be protected by a metal or wood panel beneath the ap- pliance extending beyond the full width and depth of the appliance by at least 3 inches (76.2mm) in any direction, or if the appliance is installed in an alcove or closet, the entire floor must be covered by the panel. Failure to heed this warning may result in a fire hazard.

WARNING

Chemical vapor corrosion of the flue and vent system may occur if air for combustion contains certain chemical vapors. Spray can pro- pellants, cleaning solvents, refrigerator and air conditioner refrig- erants, swimming pool chemicals, calcium and sodium chloride, waxes, bleach, and process chemicals are typical compounds which are potentially corrosive.

WARNING

Do not install in a confined area such as a closet, unless you provide ventilation air as shown in the “Locating The New Water Heater” section. Never obstruct the flow of ventilation air. If you have any doubts or questions at all, call your gas company. Failure to pro- vide ventilation air can result in a fire or explosion and can cause

DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE.

WARNING

If this water heater will be used in beauty shops, barber shops, clean- ing establishments, or self-service laundries with dry cleaning equip- ment, it is imperative that the water heater or water heaters be in- stalled so that combustion and ventilation air be taken from outside these areas. Refer to the “Locating The New Water Heater” section of this manual and also the latest edition of the National Fuel Gas Code, ANSI Z223.1, also referred to as NFPA 54 for specifics provided con- cerning air required.

WARNING

The power direct vent water heater requires its own (separate) venting system. It cannot be connected to an existing vent pipe or chimney. It must be terminated to the outdoors. Failure to properly install the venting system can result in asphyxiation, a fire or explosion and can cause DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE.

WARNING

No vent damper installation is compatible with this power vented water heater design. No vent damper, whether it is operated ther- mally or otherwise is to be installed on this power vented water heater. Alteration of any part of the factory-furnished vent assembly could result in improper operation due to restriction of flue gases, spillage of flue gases and may cause carbon monoxide poisoning.

WARNING

1.The appliance and its individual shutoff valve must be discon- nected from the gas supply piping system during any pressure testing of the gas system at test pressures in excess of 12 pound per square inch (3.5kPa).

2.The appliance must be isolated from the gas supply piping sys- tem by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal or less than 12 pound per square inch (3.5kPa).

WARNING

Soot build-up indicates a problem that requires correction before further use. Turn “OFF” gas to water heater and leave “OFF” until repairs are made, because failure to correct the cause of the sooting can result in a fire or explosion causing DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE.

WARNING

The water heater must be properly vented outdoors. Never operate the water heater unless it is vented to the outdoors and has adequate air supply to avoid risks of improper operation, explosion or asphyxiation.

WARNING

Vent termination must not be within 4 feet of any items such as gas meters, gas valves or other gas regulating equipment.

WARNING

Obstructed or deteriorated vent systems may present a serious health risk or asphyxiation.

WARNING

Minimum clearances between the water heater and combustible and non-combustible construction are: 0 inches from sides, 0 inch- es from back, 6 inches from front of jacket to closet door and 12 inches from top of jacket to combustible and non-combustible material. Minimum vent clearance: 0 inches. Provide 24 inches front clearance for servicing and adequate clearance between the jacket top and ceiling for servicing the flue area.

WARNING

HYDROGEN GAS: Hydrogen gas can be produced in a hot water system that has not been used for a long period of time (generally two weeks or more). Hydrogen gas is extremely flammable and explosive. To prevent the possibility of injury under these condi- tions, we recommend the hot water faucet be opened for several minutes at the kitchen sink before any electrical appliances which are connected to the hot water system are used (such as a dish- washer or washing machine). If hydrogen gas is present, there will probably be an unusual sound similar to air escaping through the pipe as the hot water faucet is opened. There must be no smoking or open flame near the faucet at the time it is open.

WARNING

INSULATING JACKETS: When installing an external water heater insulation jacket on a gas water heater:

a.DO NOT cover the temperature-pressure relief valve.

b.DO NOT put insulation over any part of the top of the gas water heater.

c.DO NOT put insulation over the gas control valve or gas con- trol valve/burner cover, or any access areas to the burner.

d.DO NOT let insulation around the gas water heater to get with- in 8 inches of the floor (air must get to the burner).

e.DO NOT cover or remove operating instructions, and safety related warning labels and materials affixed to the water heater.

Failure to heed this will result in the possibility of a fire or explosion.

WARNING

Flood damage to a water heater may not be readily visible or imme- diately detectible. However, over a period of time a flooded water heater will create dangerous conditions which can cause DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE. Call a qual- ified service technician or contractor to replace a flooded water heater. Do not attempt to repair the unit! It must be replaced!

CAUTION

WATER HEATERS EVENTUALLY LEAK: Installation of the water heater must be accomplished in such a manner that if the tank or any connections should leak, the flow of water will not cause dam- age to the structure. For this reason, it is not advisable to install the water heater in an attic or upper floor. When such locations cannot be avoided, a suitable drain pan should be installed under the water heater. Drain pans are available at your local hardware store. Such a drain pan must have a minimum length and width of at least 2 inches greater than the water heater dimensions and must be piped to an adequate drain. Drain pan depth must allow for access to the outer doors for servicing the ignitor and burner. Under no circum- stances is the manufacturer to be held liable for any water damage in connection with this water heater.

3

Page 3
Image 3
State Industries Commercial Gas Water Heater General Safety cont’d, DEATH, Serious Bodily INJURY, or Property Damage

Commercial Gas Water Heater specifications

State Industries has carved a niche for itself as a leader in the water heating industry, providing reliable solutions for various commercial applications. One of the standout products in their lineup is the State Industries Commercial Gas Water Heater. This powerhouse is designed to meet the demanding hot water needs of businesses, from restaurants and hotels to schools and hospitals.

One of the primary features of the State Commercial Gas Water Heater is its high efficiency. These units are engineered to deliver optimal performance while reducing energy costs. With innovative technologies such as a power vent system and advanced burner design, they maximize heat transfer and minimize heat loss. This efficiency not only translates to lower operating costs but also a reduced environmental impact, making it a smart choice for businesses looking to operate sustainably.

Durability is another hallmark of State Industries' gas water heaters. Constructed from robust materials, these units are designed to withstand the rigors of daily use in a commercial environment. The tanks are often lined with glass and reinforced to prevent corrosion, enhancing the longevity of the unit. Additionally, the use of high-quality components ensures minimal maintenance and reliable operation over time, allowing businesses to focus on their core activities rather than downtime due to equipment failure.

State's Commercial Gas Water Heaters also come equipped with advanced safety features. This includes built-in temperature controls, pressure relief valves, and flame failure protection, which work together to ensure safe operation even in high-demand situations. These features provide peace of mind to operators and help meet stringent safety standards, making them suitable for any commercial setting.

Furthermore, the versatility of these water heaters is remarkable. They are available in various sizes and configurations, allowing businesses to choose a model that perfectly fits their water heating requirements. Whether for high-volume hot water needs or continuous flow applications, State's Commercial Gas Water Heaters are designed to adapt.

In conclusion, the State Industries Commercial Gas Water Heater stands out as a top choice for businesses needing reliable and efficient hot water solutions. With its focus on efficiency, durability, safety, and versatility, this water heater is built to meet the rigorous demands of the commercial market while providing value and peace of mind to operators.