State Industries CSB 120 Recovery Rate In Gallons Per Hour At Temperature Rise Of, Solid.State

Models: CSB 52 CSB 82 CSB 120

1 2
Download 2 pages 5 Kb
Page 2
Image 2
RECOVERY RATE IN GALLONS PER HOUR AT TEMPERATURE RISE OF

COMMERCIAL

RECOVERY RATE IN GALLONS PER HOUR AT TEMPERATURE RISE OF

Standard

BTU/ Hour

3O°F

40°F

5O°F

60°F

70°F

8O°F

9O°F

100°F

110°F

120°F

130°F

140°F

kW Input

 

17°C

22°C

28°C

33°C

39°C

45°C

50°C

56°C

61°C

67°C

72°C

78°C

6

20,478

82

62

49

41

35

31

27

25

22

21

19

18

 

 

310

233

166

155

133

116

103

93

85

78

72

66

9

30,717

123

92

74

62

53

46

41

37

34

31

28

26

 

 

465

349

279

233

199

174

155

140

127

116

107

100

12

40,956

164

123

98

82

70

61

55

49

45

41

38

35

 

 

620

465

372

310

266

233

207

186

169

155

143

133

13.5

46,075

184

138

111

92

79

69

62

55

50

46

43

40

 

 

698

523

419

349

299

262

233

209

190

174

161

150

15

51,195

205

154

123

102

88

77

68

61

56

51

47

44

 

 

775

582

465

388

332

291

258

233

211

194

149

166

18

61,434

246

184

148

123

105

92

82

74

67

62

57

53

 

 

930

698

558

465

399

349

310

279

254

233

215

199

24

81,912

328

246

197

164

140

123

109

98

90

82

76

70

 

 

1241

930

744

620

532

465

414

372

338

310

286

266

27

92,151

369

276

221

185

158

138

123

111

101

92

85

79

 

 

1396

1047

938

609

509

523

465

410

391

340

322

299

30

102,390

410

307

246

205

176

154

137

123

112

102

95

88

 

 

1551

1163

930

775

665

582

517

465

423

388

358

332

36

122,868

492

369

295

246

211

184

164

148

134

123

113

105

 

 

1861

1396

1117

930

798

698

620

556

508

465

429

399

40.5

138,226

554

418

332

277

237

208

185

166

151

138

128

119

 

 

2094

1570

1256

1047

897

785

698

628

634

582

537

498

45

153,585

615

461

369

307

263

230

205

184

168

154

142

132

 

 

2326

1745

1398

1163

997

872

755

698

634

582

537

498

54

184,302

738

554

443

359

316

277

246

221

201

185

170

158

 

 

2791

2094

1675

1396

1196

1047

930

837

761

696

644

598

Figured at 1 kW (3413 BTU) = 4.1 Gallons at 100°F temperature rise.

 

 

 

 

 

Model

Tank

 

 

 

 

Dimensions

 

 

 

 

 

Inlet/

 

Approx. Ship.

 

 

 

 

 

Capacity

 

 

 

 

 

 

 

 

 

 

Outlet (NPT)

 

 

Wt. (Lbs.)

 

 

 

 

 

Number

A

 

 

 

B

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

gal.

 

litre

in.

 

 

cm

in.

cm

in.

 

cm

 

in.

 

cm

 

 

Ib

 

kg

 

 

 

 

 

CSB 52**SFE

50

 

189

55 3/4

 

142

21 3/4

 

55.2

27

 

68.6

 

1 1/4

 

3.2

 

 

265

 

120

 

 

 

 

 

CSB 82**SFE

80

 

300

60 1/4

 

153

25 1/2

64.8

31

 

78.7

 

1 1/4

 

3.2

 

 

280

 

127

 

 

 

 

CSB 120**SFE

119

 

450

62 1/4

 

158.1

29 1/2

75.0

35

 

88.9

 

1 1/4

 

3.2

 

 

390

 

177

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

kW

 

 

Model Numbers

 

 

 

 

Number

 

Element

 

 

Full Load Current In Amperes

 

 

Tank Capacity in Gallons

 

 

 

 

Of

 

 

 

Single Phase

 

 

 

 

 

 

Three Phase

Input

50

 

80

 

 

119

 

 

 

Elements

 

Wattage

 

208V

240V

277V

 

480V

 

 

208V

 

240V

480V

6

CSB 52 6 SFE

 

CSB 82 6 SFE

 

CSB 120 6 SFE

 

 

3

 

 

2,000

 

28.8

25.0

 

21.7

 

12.5

 

 

16.7

 

14.4

7.2

9

CSB 52 9 SFE

 

CSB 82 9 SFE

 

CSB 120 9 SFE

 

 

3

 

 

3,000

 

43.3

37.5

 

**32.5

 

18.8

 

 

25.0

 

21.7

10.8

12

CSB 52 12 SFE

 

CSB 82 12 SFE

 

CSB 120 12 SFE

 

 

3

 

 

4,000

 

57.7

50.0

 

43.3

 

25.0

 

 

33.3

 

28.9

14.4

13.5

CSB 52 135 SFE

 

CSB 82 135 SFE

 

CSB 120 135 SFE

 

3

 

 

4,500

 

64.9

56.3

 

**48.7

 

28.1

 

 

37.5

 

32.5

16.2

15

CSB 52 15 SFE

 

CSB 82 15 SFE

 

CSB 120 15 SFE

 

 

3

 

 

5,000

 

72.1

62.5

 

**54.2

 

31.3

 

 

41.6

 

36.1

18.0

18

CSB 52 18 SFE

 

CSB 82 18 SFE

 

CSB 120 18 SFE

 

 

3*

 

 

6,000

 

86.5

75.0

 

65.0

 

37.5

 

 

50.0

 

43.3

21.7

24

CSB 52 24 SFE

 

CSB 82 24 SFE

 

CSB 120 24 SFE

 

 

6

 

 

4,000

 

115.4

100.0

 

86.6

 

50.0

 

 

66.6

 

57.7

28.9

27

CSB 52 27 SFE

 

CSB 82 27 SFE

 

CSB 120 27 SFE

 

 

6

 

 

4,500

 

129.8

112.5

 

**97.5

 

56.3

 

 

74.9

 

65.0

32.5

30

CSB 52 30 SFE

 

CSB 82 30 SFE

 

CSB 120 30 SFE

 

 

6

 

 

5,000

 

144.2

125.0

 

**108.3

 

62.5

 

 

83.3

 

72.2

36.1

36

CSB 52 36 SFE

 

CSB 82 36 SFE

 

CSB 120 36 SFE

 

 

6*

 

 

6,000

 

173.1

150.0

 

130.0

 

75.0

 

 

99.9

 

86.6

43.3

40.5

N/A

 

CSB 82 405 SFE

 

CSB 120 405 SFE

 

9

 

 

4,500

 

194.7

168.8

 

**146.2

 

84.4

 

 

112.4

 

97.4

48.7

45

N/A

 

CSB 82 45 SFE

 

CSB 120 45 SFE

 

 

9

 

 

5,000

 

216.3

187.5

 

**162.5

 

93.8

 

 

124.9

 

108.3

54.1

54

N/A

 

CSB 82 54 SFE

 

CSB 120 54 SFE

 

 

9

 

 

6,000

 

N/A

225.0

 

194.9

 

112.5

 

 

149.9

 

129.9

65.0

*208 volt models may contain three (3) additional elements. ** Elements available in incoloy only.

SUGGESTED SPECIFICATION

 

The heater(s) shall be SandBlaster CSB Series Commercial Electric Model Number ______________ as manufactured by State Industries shall be rated at

____________kW,_______volts, ____________ phase, 60 cycle AC, and listed by Underwriters’ Laboratories and approved to the NSF Standard 5 by UL. Tank(s) shall be

________ gallon capacity. Tanks shall be 50, 80 and 119 gallon capacity and shall have 150 psi working pressure and be equipped with extruded high density anode.

All internal surfaces of the heater(s) exposed to water shall be glass-lined with an alkaline borosilicate composition that has been fused-to-steel by firing at a temperature range

of 1400°F to 1600°F. Electric heating elements shall be gold plated low watt density screw-in type. Each element shall be controlled by an individually mounted thermostat and high temperature

cut-offswitch.Allinternalcircuitsshallbefused.Theouterjacketshallbeofbakedenamelfinishandshallbeprovidedwithfullsizecontrolcompartmentforperformanceofserviceandmaintenance

throughhingedfrontpanelandshallenclosethetankwithfoaminsulation.Electricaljunctionboxwithheavydutyterminalblockshallbeprovided.Thedrainvalveshallbelocatedinthefrontforease

of servicing. Heater tank shall have a three year limited warranty as outlined in the written warranty. Manufacturer shall supply ASME rated temperature and pressure relief valve. Fully illustrated

instruction manual to be included. Meets ASHRAE 90.1b -1992 and ASHRAE/IESNA 90.1-2004.

 

For more information on this product contact:

 

State Water Heaters

 

500 Tennessee Waltz Parkway, Ashland City, TN 37015

 

800.365.0024 Toll-free USA

SOLID.STATE.

www.statewaterheaters.com

 

SCESS00508

September 2010R

 

 

 

 

Page 2
Image 2
State Industries CSB 120 Recovery Rate In Gallons Per Hour At Temperature Rise Of, Suggested Specification, Solid.State