COMMERCIAL
RECOVERY RATE IN GALLONS PER HOUR AT TEMPERATURE RISE OF
Standard | BTU/ Hour | 3O°F | 40°F | 5O°F | 60°F | 70°F | 8O°F | 9O°F | 100°F | 110°F | 120°F | 130°F | 140°F |
kW Input |
| 17°C | 22°C | 28°C | 33°C | 39°C | 45°C | 50°C | 56°C | 61°C | 67°C | 72°C | 78°C |
6 | 20,478 | 82 | 62 | 49 | 41 | 35 | 31 | 27 | 25 | 22 | 21 | 19 | 18 |
|
| 310 | 233 | 166 | 155 | 133 | 116 | 103 | 93 | 85 | 78 | 72 | 66 |
9 | 30,717 | 123 | 92 | 74 | 62 | 53 | 46 | 41 | 37 | 34 | 31 | 28 | 26 |
|
| 465 | 349 | 279 | 233 | 199 | 174 | 155 | 140 | 127 | 116 | 107 | 100 |
12 | 40,956 | 164 | 123 | 98 | 82 | 70 | 61 | 55 | 49 | 45 | 41 | 38 | 35 |
|
| 620 | 465 | 372 | 310 | 266 | 233 | 207 | 186 | 169 | 155 | 143 | 133 |
13.5 | 46,075 | 184 | 138 | 111 | 92 | 79 | 69 | 62 | 55 | 50 | 46 | 43 | 40 |
|
| 698 | 523 | 419 | 349 | 299 | 262 | 233 | 209 | 190 | 174 | 161 | 150 |
15 | 51,195 | 205 | 154 | 123 | 102 | 88 | 77 | 68 | 61 | 56 | 51 | 47 | 44 |
|
| 775 | 582 | 465 | 388 | 332 | 291 | 258 | 233 | 211 | 194 | 149 | 166 |
18 | 61,434 | 246 | 184 | 148 | 123 | 105 | 92 | 82 | 74 | 67 | 62 | 57 | 53 |
|
| 930 | 698 | 558 | 465 | 399 | 349 | 310 | 279 | 254 | 233 | 215 | 199 |
24 | 81,912 | 328 | 246 | 197 | 164 | 140 | 123 | 109 | 98 | 90 | 82 | 76 | 70 |
|
| 1241 | 930 | 744 | 620 | 532 | 465 | 414 | 372 | 338 | 310 | 286 | 266 |
27 | 92,151 | 369 | 276 | 221 | 185 | 158 | 138 | 123 | 111 | 101 | 92 | 85 | 79 |
|
| 1396 | 1047 | 938 | 609 | 509 | 523 | 465 | 410 | 391 | 340 | 322 | 299 |
30 | 102,390 | 410 | 307 | 246 | 205 | 176 | 154 | 137 | 123 | 112 | 102 | 95 | 88 |
|
| 1551 | 1163 | 930 | 775 | 665 | 582 | 517 | 465 | 423 | 388 | 358 | 332 |
36 | 122,868 | 492 | 369 | 295 | 246 | 211 | 184 | 164 | 148 | 134 | 123 | 113 | 105 |
|
| 1861 | 1396 | 1117 | 930 | 798 | 698 | 620 | 556 | 508 | 465 | 429 | 399 |
40.5 | 138,226 | 554 | 418 | 332 | 277 | 237 | 208 | 185 | 166 | 151 | 138 | 128 | 119 |
|
| 2094 | 1570 | 1256 | 1047 | 897 | 785 | 698 | 628 | 634 | 582 | 537 | 498 |
45 | 153,585 | 615 | 461 | 369 | 307 | 263 | 230 | 205 | 184 | 168 | 154 | 142 | 132 |
|
| 2326 | 1745 | 1398 | 1163 | 997 | 872 | 755 | 698 | 634 | 582 | 537 | 498 |
54 | 184,302 | 738 | 554 | 443 | 359 | 316 | 277 | 246 | 221 | 201 | 185 | 170 | 158 |
|
| 2791 | 2094 | 1675 | 1396 | 1196 | 1047 | 930 | 837 | 761 | 696 | 644 | 598 |
Figured at 1 kW (3413 BTU) = 4.1 Gallons at 100°F temperature rise.
|
|
|
|
| Model | Tank |
|
|
|
| Dimensions |
|
|
|
|
| Inlet/ |
| Approx. Ship. | |||||||||||||
|
|
|
|
| Capacity |
|
|
|
|
|
|
|
|
|
| Outlet (NPT) |
|
| Wt. (Lbs.) | |||||||||||||
|
|
|
|
| Number | A |
|
|
| B |
| C |
|
|
| |||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
| gal. |
| litre | in. |
|
| cm | in. | cm | in. |
| cm |
| in. |
| cm |
|
| Ib |
| kg | |||||
|
|
|
|
| CSB 52**SFE | 50 |
| 189 | 55 3/4 |
| 142 | 21 3/4 |
| 55.2 | 27 |
| 68.6 |
| 1 1/4 |
| 3.2 |
|
| 265 |
| 120 | ||||||
|
|
|
|
| CSB 82**SFE | 80 |
| 300 | 60 1/4 |
| 153 | 25 1/2 | 64.8 | 31 |
| 78.7 |
| 1 1/4 |
| 3.2 |
|
| 280 |
| 127 | |||||||
|
|
|
| CSB 120**SFE | 119 |
| 450 | 62 1/4 |
| 158.1 | 29 1/2 | 75.0 | 35 |
| 88.9 |
| 1 1/4 |
| 3.2 |
|
| 390 |
| 177 | ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||
kW |
|
| Model Numbers |
|
|
|
| Number |
| Element |
|
| Full Load Current In Amperes |
| ||||||||||||||||||
| Tank Capacity in Gallons |
|
|
|
| Of |
|
|
| Single Phase |
|
|
|
|
|
| Three Phase | |||||||||||||||
Input | 50 |
| 80 |
|
| 119 |
|
|
| Elements |
| Wattage |
| 208V | 240V | 277V |
| 480V |
|
| 208V |
| 240V | 480V | ||||||||
6 | CSB 52 6 SFE |
| CSB 82 6 SFE |
| CSB 120 6 SFE |
|
| 3 |
|
| 2,000 |
| 28.8 | 25.0 |
| 21.7 |
| 12.5 |
|
| 16.7 |
| 14.4 | 7.2 | ||||||||
9 | CSB 52 9 SFE |
| CSB 82 9 SFE |
| CSB 120 9 SFE |
|
| 3 |
|
| 3,000 |
| 43.3 | 37.5 |
| **32.5 |
| 18.8 |
|
| 25.0 |
| 21.7 | 10.8 | ||||||||
12 | CSB 52 12 SFE |
| CSB 82 12 SFE |
| CSB 120 12 SFE |
|
| 3 |
|
| 4,000 |
| 57.7 | 50.0 |
| 43.3 |
| 25.0 |
|
| 33.3 |
| 28.9 | 14.4 | ||||||||
13.5 | CSB 52 135 SFE |
| CSB 82 135 SFE |
| CSB 120 135 SFE |
| 3 |
|
| 4,500 |
| 64.9 | 56.3 |
| **48.7 |
| 28.1 |
|
| 37.5 |
| 32.5 | 16.2 | |||||||||
15 | CSB 52 15 SFE |
| CSB 82 15 SFE |
| CSB 120 15 SFE |
|
| 3 |
|
| 5,000 |
| 72.1 | 62.5 |
| **54.2 |
| 31.3 |
|
| 41.6 |
| 36.1 | 18.0 | ||||||||
18 | CSB 52 18 SFE |
| CSB 82 18 SFE |
| CSB 120 18 SFE |
|
| 3* |
|
| 6,000 |
| 86.5 | 75.0 |
| 65.0 |
| 37.5 |
|
| 50.0 |
| 43.3 | 21.7 | ||||||||
24 | CSB 52 24 SFE |
| CSB 82 24 SFE |
| CSB 120 24 SFE |
|
| 6 |
|
| 4,000 |
| 115.4 | 100.0 |
| 86.6 |
| 50.0 |
|
| 66.6 |
| 57.7 | 28.9 | ||||||||
27 | CSB 52 27 SFE |
| CSB 82 27 SFE |
| CSB 120 27 SFE |
|
| 6 |
|
| 4,500 |
| 129.8 | 112.5 |
| **97.5 |
| 56.3 |
|
| 74.9 |
| 65.0 | 32.5 | ||||||||
30 | CSB 52 30 SFE |
| CSB 82 30 SFE |
| CSB 120 30 SFE |
|
| 6 |
|
| 5,000 |
| 144.2 | 125.0 |
| **108.3 |
| 62.5 |
|
| 83.3 |
| 72.2 | 36.1 | ||||||||
36 | CSB 52 36 SFE |
| CSB 82 36 SFE |
| CSB 120 36 SFE |
|
| 6* |
|
| 6,000 |
| 173.1 | 150.0 |
| 130.0 |
| 75.0 |
|
| 99.9 |
| 86.6 | 43.3 | ||||||||
40.5 | N/A |
| CSB 82 405 SFE |
| CSB 120 405 SFE |
| 9 |
|
| 4,500 |
| 194.7 | 168.8 |
| **146.2 |
| 84.4 |
|
| 112.4 |
| 97.4 | 48.7 | |||||||||
45 | N/A |
| CSB 82 45 SFE |
| CSB 120 45 SFE |
|
| 9 |
|
| 5,000 |
| 216.3 | 187.5 |
| **162.5 |
| 93.8 |
|
| 124.9 |
| 108.3 | 54.1 | ||||||||
54 | N/A |
| CSB 82 54 SFE |
| CSB 120 54 SFE |
|
| 9 |
|
| 6,000 |
| N/A | 225.0 |
| 194.9 |
| 112.5 |
|
| 149.9 |
| 129.9 | 65.0 |
*208 volt models may contain three (3) additional elements. ** Elements available in incoloy only.
SUGGESTED SPECIFICATION |
| |
The heater(s) shall be SandBlaster CSB Series Commercial Electric Model Number ______________ as manufactured by State Industries shall be rated at | ||
____________kW,_______volts, ____________ phase, 60 cycle AC, and listed by Underwriters’ Laboratories and approved to the NSF Standard 5 by UL. Tank(s) shall be | ||
________ gallon capacity. Tanks shall be 50, 80 and 119 gallon capacity and shall have 150 psi working pressure and be equipped with extruded high density anode. | ||
All internal surfaces of the heater(s) exposed to water shall be | ||
of 1400°F to 1600°F. Electric heating elements shall be gold plated low watt density | ||
throughhingedfrontpanelandshallenclosethetankwithfoaminsulation.Electricaljunctionboxwithheavydutyterminalblockshallbeprovided.Thedrainvalveshallbelocatedinthefrontforease | ||
of servicing. Heater tank shall have a three year limited warranty as outlined in the written warranty. Manufacturer shall supply ASME rated temperature and pressure relief valve. Fully illustrated | ||
instruction manual to be included. Meets ASHRAE 90.1b |
| |
For more information on this product contact: |
| |
State Water Heaters |
| |
500 Tennessee Waltz Parkway, Ashland City, TN 37015 |
| |
800.365.0024 | SOLID.STATE. | |
www.statewaterheaters.com | ||
|
SCESS00508 | September 2010R |
|
|
|
|