C O M M E R C I A L
TITAN™
Commercial Oil Water Heater
SPECIFICATIONS
| Storage |
| Firing |
| Output (Gallons) |
|
|
| Dimensions In Inches |
|
|
| Approximate | Water | ||||||||||
|
|
|
|
|
|
|
|
|
|
| Motor | Shipping | ||||||||||||
| Capacity | Input* |
|
|
|
|
|
|
|
|
| |||||||||||||
Model Number |
|
| Recovery |
|
|
|
|
| Connections | |||||||||||||||
U.S. | BTU/Hr. | Rate |
|
|
|
|
|
|
|
|
|
|
|
| HP | Wt. (lbs.) | ||||||||
| GPH |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
| Gallons |
| 80°F Rise |
| 100°F Rise |
| 140°F Rise | A |
| B |
| C |
| D |
| E |
| Standard |
| ASME | In |
| Out | |
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
GPO 86 199OE | 86 | 199,000 | 1.42 | 241 |
| 193 |
| 138 | 743⁄4 |
| 673⁄4 |
| 27 |
| 6 |
| 231⁄8 | 1⁄8 | 568 |
| — | 11⁄2 |
| 11⁄2 |
GPO 86 245OE | 86 | 245,000 | 1.75 | 297 |
| 238 |
| 170 | 743⁄4 |
| 673⁄4 |
| 27 |
| 8 |
| 231⁄8 | 1⁄8 | 557 |
| — | 11⁄2 |
| 11⁄2 |
GPO 84 315OE** | 84 | 315,000 | 2.25 | 382 |
| 305 |
| 218 | 743⁄4 |
| 673⁄4 |
| 27 |
| 8 |
| 231⁄8 | 1⁄8 | 557 |
| 668 | 11⁄2 |
| 11⁄2 |
GPO 75 385OE** | 75 | 385,000 | 2.75 | 467 |
| 373 |
| 267 | 743⁄4 |
| 65 |
| 251⁄4 |
| 8 |
| 233⁄4 | 1⁄8 | 638 |
| 730 | 11⁄2 |
| 11⁄2 |
GPO 75 455OE** | 75 | 455,000 | 3.25 | 552 |
| 441 |
| 315 | 743⁄4 |
| 66 |
| 251⁄4 |
| 8 |
| 233⁄4 | 1⁄8 | 647 |
| 748 | 11⁄2 |
| 11⁄2 |
GPO 69 700OE** | 69 | 700,000 | 5.00 | 848 |
| 679 |
| 485 | 793⁄4 |
| 703⁄8 |
| 303⁄16 |
| 10 |
| 293⁄8 | 1⁄8 | 739 |
| 853 | 11⁄2 |
| 11⁄2 |
*Based on No.2 fuel oil. Capacity ratings are actual heater performance at 80% thermal efficiency. **These models are available with ASME construction. When ordering ASME construction, add “A” to
end of model model. Example: GPO 69 700OE A
NOTE: Above 2000´ altitude, input ratings should be reduced 4% for each 1000´ above sea level.
|
|
|
| 37 ˝ |
|
| D |
| 11⁄2˝ NPT INLET & |
|
|
| OUTLET OPENINGS | |
|
|
|
| |
|
|
|
| 1˝ NPT T&P VALVE OPENING |
|
|
| 273⁄4˝ | |
ELEC. |
|
| ||
ENTR | Y |
|
|
|
|
|
| ||
A |
|
| ||
|
|
|
| B |
C
E
ASME
(ON SELECTED MODELS)
Water heater(s) shall be commercial oil model number______________or equivalent. Heater(s) shall have a minimum oil firing rate of ______________gph at 100°F temperature
rise and a storage capacity of _________________gallons. The 160 psi working pressure tank shall be
fused to the steel at 1600° and be equipped with
interrupted ignition and be equipped with primary controls which will provide for 15 second safety shutdown in the event of flame failure. The heater(s) shall be factory equipped with primary controls which will provide for 15 second safety shutdown in the event of flame failure. The heater(s) shall be factory equipped with temperature limiting device, drain valve, flame observation port and 180° adjustable thermostat having upper and lower sensing bulbs which average the water temperatures at the top and bottom of the tank for maximum water temperature control. A pressure and temperature relief valve shall be furnished and installed by the factory. Heater tank shall have a 3 year limited warranty against corrosion and tank failure due to sediment buildup as outlined in the warranty.
CAUTION: Unit must be installed on
MULTIPLE INSTALLATIONS
Furnish and install __________________models as specified with a State (2, 3, or 4) heater manifold kit, package number _____________.
For more information on Titan™ contact: State Water Heaters
500 Tennessee Waltz Parkway, Ashland City, TN 37015
SCOSS00105 | July 2008R |