TITAN™ POWERED
BURNER
|
|
|
| FIRST |
| ||||
| BTU |
|
|
| PER HOUR AT °F | ||||
|
|
| HOUR |
| |||||
|
|
|
| TEMPERATURE RISE | |||||
| INPUT | Gallons |
| RATING | GPH | ||||
MODEL | TANK | 40°F | 100°F | 140°F | |||||
PER | or | 100° F | or | ||||||
NUMBER | HOUR | Litres | SIZE | RISE | LPH | 4°C | 56°C | 78°C | |
GPG85 540 NEA | 540,000 | U.S. Gallons | 85 | 583 | GPH | 1309 | 523 | 374 | |
GPV85 540 NEA | Litres | 321.7 | 2206.7 | LPH | 4954.6 | 1979.6 | 1415.6 | ||
| |||||||||
GPG85 650 NEA | 650,000 | U.S. Gallons | 85 | 690 | GPH | 1579 | 630 | 450 | |
GPV85 650 NEA | Litres | 321.7 | 2611.7 | LPH | 5976.5 | 2384.6 | 1703.3 | ||
| |||||||||
GPG85 740 NEA | 740,000 | U.S. Gallons | 85 | 778 | GPH | 1794 | 718 | 512 | |
GPV85 740 NEA | Litres | 321.7 | 2944.7 | LPH | 6790.3 | 2717.6 | 1937.9 | ||
| |||||||||
|
|
|
|
|
|
|
|
|
Based on 80% Thermal Efficiency obtained in State engineering laboratories.
To compensate for effects of high altitude above 2,000 feet, recovery ratings should be reduced 5% for every 1,000 feet above sea level.
Current Draw (120V, 60Hz, 1 Phase): 6.0 Amps
DIMENSIONS AND WEIGHT – ALL MODELSInches |
|
|
| DIMENSIONS |
|
|
| GAS | SHIPPING | |||
or |
|
|
|
|
|
|
|
|
| |||
A | B | C | D | E | F | G | H | I | CONN.*** | WEIGHT | ||
CM | ||||||||||||
Inches | 73 | 9 | 93 | 1˝ | 950 Lbs. | |||||||
CM | 205.1 | 185.4 | 81.9 | 22.9 | 67.3 | 67.3 | 236.2 | 74.9 | 123.2 | - | 431.8 Kg |
*D dimension is for atmospheric vent size (GPG models).
**E dimension is for direct and sidewall vent size (GPV models).
***Minimum gas supply pipe is
SUGGESTED SPECIFICATION
Water heater(s) shall be State Model ________________ or equal, with maximum storage capacity of 85
gallons, an input rating of ___________________ BTU/Hr., a recovery rating of ____ GPH at 100ºF temperature
rise, and minimum thermal efficiency of 80%. Heater(s) shall meet ASHRAE/IESNA
Venting: GPG heater(s) shall be supplied with a Barometric Draft Regulator for conventional atmospheric venting.
GPV heater(s) shall be supplied with an optional vent kit allowing for horizontal sidewall venting or direct venting.
Burner and Controls: Burner(s) shall be
For complete information on limited warranties, consult written warranty, or contact the State Customer Care Center,
State Industries, Inc. reserves the right to make product changes or improvements without prior notice.
For Additional Technical Information,
PHONE
STATE WATER HEATERS
500 Tennessee Waltz Parkway, Ashland City, TN 37015 www.statewaterheaters.com
Page 2 of 2
SCGSS00205 | © 2005 State Industries, Inc. | Printed in U.S.A. |