State Industries SBD85500NE installation considerations, Rough In Dimensions, Front View

Models: SBD85500PE SBD85500NE

1 52
Download 52 pages 9.88 Kb
Page 8
Image 8
installation considerations

installation considerations

Rough In Dimensions

FRONT VIEW

BACK VIEW

TOP

OUTLET

1 1/2” NPT

F

TOP INLET

1 1/2” NPT

TOP VIEW

FIGURE 5

TABLE 1. ROUGH-IN-DIMENSIONS

 

 

 

 

 

 

Dimensions in Inches/cm

 

 

 

 

 

 

Connections

 

 

Approx. Ship Weight

 

Input Rate

Approximate

 

 

 

 

 

 

 

Inlet (NPT)

Outlet (NPT)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

Btu/Hr

Tank Cap

 

 

 

 

 

 

Gas

 

Vent

 

 

 

 

 

 

 

 

Std.

ASME

 

Kw/Hr

G/L

A

B

C

D

E

F

Inlet

H

Dia

J

Top

 

Front

Back

Top

Front

Back

Lbs/

Lbs/

 

 

 

 

 

 

 

 

 

G

 

I

 

 

 

 

 

 

 

 

Kgs.

Kgs.

SBD85500NE/

500,000

85

81.50

17.50

77.25

67.50

27.13

21.00

1.00

67.50

8.00

27.75

1.50

 

1.50

1.50

1.50

1.50

1.50

812

857

SBD85500PE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SBD85500NE/

147

322

207

44

196

171

69

53

3

171

20

70

1.50

 

1.50

1.50

1.50

1.50

1.50

368

389

SBD85500PE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TABLE 2. RECOVERY CAPACITIES, based on 80% efficiency

 

Input Rate

Approximate

 

 

 

Recovery Rating Capacities (GPH and LPH) at temperature rise indicated

 

 

 

Model

Btu/Hr

Tank Cap

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30°F

40°F

50°F

 

60°F

70°F

80°F

90°F

100°F

110°F

 

120°F

130°F

140°F

 

Kw/Hr

G/L

17°C

22°C

28°C

 

33°C

39°C

44°C

50°C

56°C

61°C

 

67°C

72°C

78°C

SBD85500NE/

500,000

85

1616

1212

970

 

808

693

606

539

485

441

 

404

373

346

SBD85500PE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SBD85500NE/

147

322

6118

4588

3671

 

3059

2622

2294

2039

1835

1668

 

1529

1412

1311

SBD85500PE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TABLE 3. GAS AND ELECTRICAL CHARACTERISTICS

Model

Gas Type

Gas Supply Pressure

Gas Manifold Pressure

Volts / Hz

Amperes

Minumum

Maximum

 

 

 

 

 

SBD85500NE/

Natural

4.5" W.C. (1.12 kPa)

14" W.C. (3.48 kPa)

3.5" W.C. (0.87 kPa)

120/60

<5

SBD85500PE

 

 

 

 

 

 

SBD85500NE/

Propane

11" W.C. (2.74 kPa)

14" W.C. (3.48 kPa)

10" W.C. (2.49 kPa)

120/60

<5

SBD85500PE

 

 

 

 

 

 

8

Page 8
Image 8
State Industries SBD85500NE, SBD85500PE installation considerations, Rough In Dimensions, Front View, Back View, Top View