2.3. Compressed air supply

For operation of the valve, a com- pressed-air supply (1/4“) is needed.

Check compressed air piping for correct installation and assembly.

Check fittings, length and quality of the hose connections for agree- ment with requirements.

The operating pressure is 5-6 bar

(72 - 87 PSI) (system overpressure).

Check the compressed air supplied by the plant’s supply network.

Adjust compressed air pressure to

5-6 bar (72-87 PSI) (system overpressure).

Compressed air must be dewatered and oiled.

Maintenance unit

Install a maintenance unit (pressure reducer with water separator and oiler) if re- quired.

Connect the unit to the plant’s supply network by means of a hose.

L

F

SM3-635b

Depressurize compressed air supply lines which must be opened.

Compressed air must be dewatered and oiled.

Adjust pressure to a max. value of 6 bar (87 PSI) (system overpressure).