3.1. Maintenance intervals

 

Daily:

Check warning signs on equipment for good

 

legibility and completeness.

 

Check the oil level in the oiler.

 

Empty the water separator.

 

Check operating pressure of the plant’s supply

 

network (5-6 bar system overpressure).

 

Check waste level in the collecting bin.

Monthly:

Clean the fiter cartridges

 

(depending on accumulation of dust earlier!).

Every six months:

Check all electrical and mechanical connections

 

for secure fit.

 

Replace the filter cartridges

 

(depending on accumulation of dust earlier!).

 

Check the sealing rings of the nonreturn valve

 

and the outlet flap.

Yearly:

Replace the sealing rings of the nonreturn valve

 

and the outlet flap.

&

The service intervals refer to a 3-shift operation.

 

 

F

The given maintenance intervals are average values.

Check whether in your individual case the maintenance inter-

 

vals must be shortened.

 

 

SM3-635b