Sterling SM3-615a operating instructions Adjust the flap switch

Models: SM3-615a

1 29
Download 29 pages 5.97 Kb
Page 21
Image 21

SSK 5-DURO

4.2.2. Adjust the flap switch

Remove the connecting plug “flap switch” from the connection housing of the hopper.

Connect an ohmmeter to PINS 1 and 4 of the connecting plug “flap switch”.

Release the nuts (A) of the flap switch (B) until the support can be displaced.

Open the outlet flap (C) so far that the front tip of the outlet flap is approx. 35-40 mm (1.48-1.67 in.) away from the sealing sur- face.

Displace the flap switch (B) until the con- tact of the magnet switch is closed.

Tighten the nuts (A) of the flap switch.

Check the adjustment:

In case of free hanging outlet flap (empty hopper loader) the contact of the magnet switch must be closed.

C

B

A

Flap switch

If the outlet flap cannot be properly adjusted, replace the flap switch or the outlet flap with magnet.

Install the hopper.

&

Order numbers

 

flap switch:

ID 28839

outlet flap with magnet:

ID 23093

 

 

SM3-615a

Maintenance 20

Page 21
Image 21
Sterling SM3-615a operating instructions Adjust the flap switch