31
BLOWBACK
BLOWBACK Indicator
The BLOWBACK indicator lights when the air solenoid is open.
MATERIAL "B"
MATERIAL “B” Indicator
The MATERIAL “B” indicator lights when the Material B port is open.
5-4 Starting Up the Hopper Loader for the First Time Using the Series One Plus Controller
Non-Proportioning Models
1. Insert the pickup wand into the material supply.
2. Turn on the compressed air to the hopper loader.
3. Apply power to the controller.
Note: Press and hold the
CLEAR
UP key and DOWN key together
simultaneously while applying power to restore all factory
defaults.
As the controller powers up, the screen displays in succession:
PLUS
for three seconds
the software version number
n.nn
the standby mode display.
4. Press the
S
START/STOP
START/STOP/SELECT/SET key to start the
hopper loader.
The vacuum motor conveys material until the proximity sensor
indicates the hopper loader is full or the factory-pre-set default
maximum vacuum time of sixty seconds passes, whichever comes
first. The VACUUM and MATERIAL “A” LEDs light and the
LED display shows the elapsed conveying time.