STT 110 / STT 160

5.1. Maintenance schedule

Daily:

Check warning signs on equipment for good

 

legibility and completeness

 

Clean return air filters and casing (depending

 

on dust build-up)

Weekly:

Check main switch for proper function

 

Check the signal lamps for proper functioning

Every six months:

Change return air filters (depending on dust build-up)

 

Clean air filter of the suction box

 

All electrical and mechanical connections

 

should be checked to see if they fit securely

Annually:

Dewpoint should be checked (only by

 

Sterling service personnel)

Whenever the

 

material is changed:

The drying hopper and suction box must be cleaned

&

F

The service intervals refer to a 3-shift operation.

The given maintenance intervals are average values.

Check whether in your individual case the maintenance intervals must be shortened.

SM2-605

Maintenance 5-3

Page 27
Image 27
Sterling STT 160 manual STT 110 / STT Maintenance schedule