STT 110 / STT 160

Turn the release switches “Hopper” (ST1 - ST6) at “I” position.

Turn the thermo regulator to +80 °C (176°F) for the drying temperature.

Press the “PGM” key.

Set by means of the arrow keys the drying temperature to “80".

After 2 seconds the display flashes and the value is stored.

Press the “EXIT” key (the setpoint value and the actual value of the drying temperature are displayed).

EXIT

After 2 hours turn the release switches “Hopper” (ST1 - ST6) at “0” position.

Turn the release switch “Timer” at position:

L

Wait until the blower has stopped.

The run on time of the blower is 10 minutes.

If there is a return air cooler installed, switch off its coolant circuit. Switch off the main switch of the dryer.

&

SM2-605

The signal lamp “power” goes off.

Start up 3-3

Page 18
Image 18