STT 110 / STT 160
Turn the release switches “Hopper” (ST1 - ST6) at “I” position.
Turn the thermo regulator to +80 °C (176°F) for the drying temperature.
Press the “PGM” key.
Set by means of the arrow keys the drying temperature to “80".
After 2 seconds the display flashes and the value is stored.
Press the “EXIT” key (the setpoint value and the actual value of the drying temperature are displayed).
EXIT
After 2 hours turn the release switches “Hopper” (ST1 - ST6) at “0” position.
Turn the release switch “Timer” at position:
L
Wait until the blower has stopped.
The run on time of the blower is 10 minutes.
If there is a return air cooler installed, switch off its coolant circuit. Switch off the main switch of the dryer.
&
The signal lamp “power” goes off.