-10-

D.3.4 Connect the Solar modules: SOLAR IN +/-

Solar modules are connected on these terminals. Under no circumstances should any other energy source i.e. wind generator be connected to these terminals. Depending on the power of the modules, the cable cross section should be 2.5 up to 6mm². Before connecting it is necessary to check with a Voltmeter that the

voltage of the Module meets the following values:

 

Invertek DAI -1500C

-12xx / DAI - 3000C

-12xx

17-25V / 30A

Invertek DAI -1500C

-24xx / DAI - 3000C

- 24xx

34-45V / 30A.

D.3.5 Connection to Aux1 & AUX2:

On these three terminals is a potential free change-over contact capable of switching a maximum current and voltage of 16A/250V ac. The “ multi-display “ on the front of Combi can show the status of these contacts.

D.3.6 Connection to Remote control unit ( optional ):

The Remote control unit RCC-A is connected in the “Remote control” of front panel with a RJ11 / 6 connector. The Remote Control can be plugged IN at any time. Push in the connector, without forcing it, until you hear the ”click:, now the connector is locked in place. The same applies to the plug at the Remote control unit. The length of the cable for the Remote control should not exceed 15m, is comes standard with 3m cable.

Page 13
Image 13
Sterling Power Products DAI-1500C-24xx, DAI-3000C-24xx Connect the Solar modules Solar in +, Connection to Aux1 & AUX2