-12-

 

E.3 LED INDICATOR:

LED Blink

LED

Name

L ED ON

1

AC IN

1. Input voltage normal, and

Has input power, but

 

 

position ”transfer

voltage or frequency is not

 

 

Voltage Level”

in the allowance range.

 

 

(150VAC~240VAC)

 

 

 

2. Input voltage frequency

 

 

 

range in between(45~60Hz)

Green Blink : Battery

2

CHARGER

Green : Battery charger is

 

 

working.

charger is standby.

 

 

 

Orange Blink : Battery

 

 

 

charger is disable.

3SOLAR PANEL Solar module is delivering energy.

 

 

 

-----------------------------

 

 

 

 

4

SOLAR

Solar charger is working.

 

 

CHARGER

 

------------------------------

 

 

 

No voltage at the “AC

5

AC OUT

There is voltage at the “AC OUT”

 

 

terminal.

OUT” terminal.

 

 

 

Green Blink : Inverter is

6

INVERTER

Green : Inverter is working.

 

 

 

standby

 

 

 

Orange Blink : Inverter is

 

 

 

disable.

 

 

 

 

7

EQUALIZE

In Equalize charging

 

 

 

Process

------------------------------

 

 

 

 

 

 

of Battery.

8

BATTERY

Approx state of charge or discharge

 

 

 

Green Blink :BYPASS

9

BYPASS

Green : BYPASS switch is active

 

 

AC IN voltage is being sent

switch standby.

 

 

directly to AC OUT terminal

Orange Blink : BYPASS

 

 

 

switch disable

 

 

 

Red Blink : Auto-Restart

10

RUN/STOP

Green : Invertek turn on.

 

 

Red : Invertek turn off.

is in use

 

 

 

 

LED OFF

No input power

--------------

1.Solar module aren’t connect or

2.Day or Night / (cloudy day)

Solar charger is disabled.

-------------

--------------

Disable Equalize charging function

---------------

---------------

Page 15
Image 15
Sterling Power Products DAI-1500C-12xx, DAI-3000C-24xx, DAI-1500C-24xx, DAI-3000C-12xx user manual LED Indicator