3.14 EXTENDED STORAGE

Refer to the following steps for storage of the freezer over any long period of shutdown time:

A.Turn both FREEZING CYLINDER OFF-ON switches to the OFF position.

B.Disconnect (unplug) from the electrical supply source.

C.Clean thoroughly with a warm water detergent all parts that come in contact with the mix. Rinse in clear water and dry all parts. Do not sanitize.

NOTE

Do not let the cleaning solution stand in the hopper or in the freezer barrel during the shutdown period.

D.Remove, disassemble and clean the front door, mix inlet regulator and auger parts. Place the auger flights in a plastic bag with a moist paper towel to prevent them from becoming brittle.

E.On water cooled freezers, shut off and disconnect water supply at rear of freezer; run compressor for 2-3 minutes to open water valve, and blow out all water first through inlet then outlet line, using air or carbon dioxide.

3.15 PRODUCT CONSISTENCY ADJUSTMENT

The freezer's control system monitors the consistency (firmness) of the product (mix) in each freezing cylinder. The program module senses the consistency of the product and shuts off the drive motor and refrigeration system when the pre-programmed consistency is reached. The control panels on the front of the freezer allow the operator to adjust each freezing cylinder to create the desired product consistency.

A. Place the FREEZING CYLINDER OFF/ON switch in the ON position.

B. Press the SET button on the Control Panel once. Fine Adj will appear on the LCD screen (Fig. 30).

C. Press the up arrow button (⇑) until the desired consistency setting is displayed. The higher the number, the greater the product consistency. The control may be set from 1 to 9. Each time the up arrow (⇑) button is pressed, the value will increase by 1 until the value reaches 9, then restart at 0. The 0 setting cannot be set.

D. Press the SET button once to save the setting change and return to the current mode display.

Fine Adj 1-9 5

Figure 30. Product Conststency Control

3.16 LOCKING OUT CONTROL PANEL

The IntelliTec control has a tamper proof mode to prevent unauthorized use. When set, all buttons on the control panel are disabled. To lock out the control panel:

A. Press and hold the PUSH TO FREEZE button for 5 seconds.

B. While still holding the PUSH TO FREEZE button, press the CLEAN button once.

C. Release both buttons. An astrisk (*) will apear after the word MODE on the display, indicating that the control is in the lock out mode.

D. To unlock the control panel, repeat steps A, B and C.

19