Allow the mix to agitate in freezer barrel until the mix has

K.

Open spigot to expel water. When the hopper or pail

become a liquid.

 

is empty, place the mix pump switch and main drive

 

 

switch in the OFF position. Allow freezer barrel to

D. Place the mix pump in the ON position. Open spigot

 

drain completely.

and pump liquid mix through the freezer. When empty,

L.

Repeat steps E-K using mild detergent solution.

place main drive switch and the mix pump switches

in the OFF position.

 

 

E.Close spigot and fill hopper (hopper models) with approximately two gallons of cold tap water.

NOTE

On remote models, place mix pump suction tube into the pail of cold tap water.

F.Open air bleed valve on the front door by pushing valve in and holding.

G.Place the mix pump switch in the ON position.

H.Let the cold water fill freezer to air bleed valve, then close the valve by pulling out to lock in place.

I.Place the main drive switch in the CLEAN position.

J.Allow water to agitate until the inside surface of front door has rinsed clean.

M.Repeat steps E-K using 120 to 130° F (49-54° C) hot rinse water.

3.15DISASSEMBLYAND ASSEMBLY OF FRONT DOOR (MODEL 217 AND 237R)

To aid in the disassembly of the front door, refer to Figure 11 and the following steps:

CAUTION

TURN FREEZER OFF AT MAIN DRIVE SWITCH BEFORE DISASSEMBLING FOR CLEANING OR SERVICING.

A.Disassembly of front door.

1.Remove the front door by unscrewing the black knobs.

CAUTION

HAZARDOUS ROTATING BLADES-DO NOT OPERATE UNIT WITH FRONT DOOR OR SPIGOT REMOVED.

Model 237R

Model 217/225

Front Door

Front Door

 

 

 

"O" Ring placed INSIDE spigot extension CASTLE TYPE ONLY

È

Figure 11

Front Door Disassembly

14