FCP and SES Commands

8946121402 3-7

The field swValid is bit mapped and indicates which subsequent fields within the page are
valid. The bit position for subsequent fields starts from 0, as indicated in the Field # column ofTable3-10. For example, if the fields: Current_Date,Boot_Date and

Number_of_Sensors are valid, it contains the hex value of 0003h.

Sensor Table Page

If requested using the Send Diagnostic or Receive Diagnostic Result command, the SESDreturns the response shown in Table3-11.

Fabric Page

If requested using the Send Diagnostic or Receive Diagnostic Result command, the
SESD returns the response shown in Table3-12.
Table 3-11 Sensor Table Page Format
Byte/Bit Field # Access 7 6 5 4 3 2 1 0
0 na na Page Code = 81h
1 na na Reserved
2 .. 3 na na Page Length =
n
- 3
4 .. 7 na na swNumEntries=
i
– specifies the number of entries received
for bytes 8 -91, if the number is 5 there are 5 complete
outputs for byte 8 - 91.
8 .. 11 na ro swValidity[0]
12 .. 15 0 ro swSensorIndex[0]
16 .. 19 1 ro swSensorType[0]
20 .. 23 2 ro swSensorStatus[0]
24 .. 27 3 ro swSensorValue[0]
28 .. 91 4 ro swSensorInfo[0]
.. ... more instances of swSensorEntry (swValidity .. swSensorInfo) if applicable ...
(

n-64

)..(
n-1
) 4 ro swSensorInfo[
i-1
]
Table 3-12 Format of Fabric Page
Byte/Bit Field # Access 7 6 5 4 3 2 1 0
0 na na Page Code = 82h
1 na na Reserved
2 .. 3 na na Page Length = 20
4 .. 7 na na swValid
8 .. 11 0 ro swDomainID