FCP and SES Commands

3-12 8946121402

If the field, EVPD is set to 1, then the value of the page code may be set to one of the codesshown in Table3-18.If the page code is set to 00h, the SESD will return codes shown in Table3-19.If the page code is set to 80h, the SESD will return codes shown in Table3-20.
Table 3-18 Page Codes
Page Code Description
00h Supported vital product data pages
80h Unit Serial Number Page
83h Device Identification Page
Table 3-19 SESD Return Codes for 00h
Byte/Bit 7 6 5 4 3 2 1 0
0 Peripheral qualifier = 0 Peripheral Device Type = 0Dh
1 Page Code = 00h
2 Reserved
3 Page length = 3
4 00h
5 80h
6 83h
Table 3-20 SESD Return Codes for 80h
Byte/Bit 7 6 5 4 3 2 1 0
0 Peripheral qualifier = 0 Peripheral Device Type = 0Dh
1 Page Code = 80h
2 Reserved
3 Page length = 24
4 Product Serial Number =

the switch World_wide Name in ASCII string format

E.g. “10:00:00:60:69:00:01:b4 ”
...
27